ADuM6132 Data Sheet
Parameter Symbol Min Typ Max Unit Test Conditions/Comments
Part-to-Part Matching
1
60 ns C
L
= 200 pF
Output Rise Time (10% to 90%) t
R
15 ns C
L
= 200 pF
Output Fall Time (10% to 90%) t
F
15 ns C
L
= 200 pF
1
See the Terminology section.
2
I
DDA
is supplied by the output of the integrated isolated dc-to-dc power supply. I
DDB
is supplied by an external power connection to the V
DDB
pin. See Figure 16.
3
Duration less than 1 second. Average output current must conform to the limit shown in the Absolute Maximum Ratings section.
4
Undervoltage lockout (UVLO) holds the outputs in a low state if the corresponding input or output power supply is below the referenced threshold. Hysteresis is built
into the detection threshold to prevent oscillations and noise sensitivity.
PACKAGE CHARACTERISTICS
Table 2.
Parameter Symbol Min Typ Max Unit Test Conditions/Comments
Resistance (Input Side to High-Side Output)
1
R
I-O
10
12
Ω
Capacitance (Input Side to High-Side Output)
1
C
I-O
2.0 pF
Input Capacitance C
I
4.0 pF
Junction-to-Ambient Thermal Resistance θ
JA
45 °C/W 4-layer PCB
1
The device is considered a two-terminal device: Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together.
REGULATORY INFORMATION
Table 3.
UL CSA VDE (Pending)
Recognized under UL 1577
component recognition program
1
Approved under CSA Component Acceptance
Notice #5A
Certified according to DIN V VDE V 0884-10
(VDE V 0884-10):2006-12
2
Single protection,
3750 V rms isolation voltage
Basic insulation per CSA 60950-1-03 and IEC 60950-1,
400 V rms (566 V peak) maximum working voltage
Reinforced insulation per CSA 60950-1-03 and
IEC 60950-1, 250 V rms (354 V peak) maximum
working voltage
Reinforced insulation, 560 V peak
1
In accordance with UL 1577, each ADuM6132 is proof-tested by applying an insulation test voltage ≥ 4500 V rms for 1 second (current leakage detection limit = 10 µA).
2
In accordance with DIN V VDE V 0884-10, each ADuM6132 is proof-tested by applying an insulation test voltage ≥ 1050 V peak for 1 second (partial discharge detection
limit = 5 pC). The asterisk (*) marking branded on the component designates DIN V VDE V 0884-10
approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 4.
Rated Dielectric Insulation Voltage 3750 V rms 1 minute duration
Minimum External Air Gap (Clearance)
Measured from input terminals to output
terminals, shortest distance through air
Minimum External Tracking (Creepage) L(I02) >8.0 mm
Measured from input terminals to output
terminals, shortest distance path along body
Minimum Internal Gap (Internal Clearance) 0.017 min mm Insulation distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI >175 V DIN IEC 112/VDE 0303 Part 1
Isolation Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1)
Rev. B | Page 4 of 16