Data Sheet ADuM5400
Rev. B | Page 5 of 16
PACKAGE CHARACTERISTICS
Table 5.
Parameter Symbol Min Typ Max Unit Test Conditions/Comments
RESISTANCE AND CAPACITANCE
Resistance (Input-to-Output)
R
10
Ω
Capacitance (Input-to-Output)
C
2.2 pF f = 1 MHz
Input Capacitance
2
C
4.0 pF
IC Junction-to-Ambient Thermal
Resistance
θ
JA
45 °C/W Thermocouple located at center of package underside;
test conducted on 4-layer board with thin traces
3
1
This device is considered a 2-terminal device; Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together.
2
Input capacitance is from any input data pin to ground.
3
See the Thermal Analysis section for thermal model definitions.
REGULATORY INFORMATION
The ADuM5400 is approved by the organizations listed in Table 6. Refer to Table 11 and to the Insulation Lifetime section for details
regarding the recommended maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 6.
UL
CSA VDE (Pending)
Recognized Under 1577 Component
Recognition Program
1
Approved under CSA Component
Acceptance Notice #5A
Certified according to IEC 60747-5-2
(VDE 0884 Part 2):2003-01
2
Single Protection, 2500 V rms
Isolation Voltage
Testing was conducted per CSA 60950-1-07
and IEC 60950-1 2
nd
Ed. at 2.5 kV rated voltage
Basic insulation at 600 V rms (848 V peak)
working voltage
Reinforced insulation at 250 V rms (353 V peak)
working voltage
Basic insulation, 560 V peak
File E214100 File 205078 File 2471900-4880-0001
1
In accordance with UL 1577, each ADuM5400 is proof tested by applying an insulation test voltage ≥ 3000 V rms for 1 second (current leakage detection limit = 10 µA).
2
In accordance with IEC 60747-5-2 (VDE 0884 Part 2):2003-01, each ADuM5400 is proof tested by applying an insulation test voltage ≥ 1590 V peak for 1 second (partial
discharge detection limit = 5 pC). The asterisk (*) marking branded on the component designates IEC 60747-5-2 (VDE 0884 Part 2):2003-01
approval.
INSULATION AND SAFETY RELATED SPECIFICATIONS
Table 7. Critical Safety Related Dimensions and Material Properties
Parameter Symbol Value Unit Test Conditions/Comments
Rated Dielectric Insulation Voltage 2500 V rms 1 minute duration
Minimum External Air Gap L(I01) 8.0 mm Measured from input terminals to output terminals,
shortest distance through air
Minimum External Tracking (Creepage) L(I02) 7.6 mm Measured from input terminals to output terminals,
shortest distance path along body
Minimum Internal Gap (Internal Clearance) 0.017 min mm Distance through insulation
Tracking Resistance (Comparative Tracking
Index)
DIN IEC 112/VDE 0303 Part 1
Material Group IIIa Material group (DIN VDE 0110, 1/89, Table 1)