16 Mbit / 32 Mbit Multi-Purpose Flash Plus
SST39VF1601 / SST39VF3201
SST39VF1602 / SST39VF3202
Not Recommended for New Designs
A
Microchip Technology Company
Product Identification
The Product Identification mode identifies the devices as the SST39VF1601, SST39VF1602,
SST39VF3201, or SST39VF3202, and manufacturer as SST. This mode may be accessed software
operations. Users may use the Software Product Identification operation to identify the part (i.e., using
the device ID) when using multiple manufacturers in the same socket. For details, see Table 6 for soft-
ware operation, Figure 12 for the Software ID Entry and Read timing diagram and Figure 22 for the
Software ID Entry command sequence flowchart.
Product Identification Mode Exit/CFI Mode Exit
In order to return to the standard Read mode, the Software Product Identification mode must be exited.
Exit is accomplished by issuing the Software ID Exit command sequence, which returns the device to
the Read mode. This command may also be used to reset the device to the Read mode after any inad-
vertent transient condition that apparently causes the device to behave abnormally, e.g., not read cor-
rectly. Please note that the Software ID Exit/CFI Exit command is ignored during an internal Program
or Erase operation. See Table 6 for software command codes, Figure 14 for timing waveform, and Fig-
ures 22 and 23 for flowcharts.
Security ID
The SST39VF160x/320x devices offer a 256-bit Security ID space. The Secure ID space is divided into
two 128-bit segments - one factory programmed segment and one user programmed segment. The
first segment is programmed and locked at SST with a random 128-bit number. The user segment is
left un-programmed for the customer to program as desired.
To program the user segment of the Security ID, the user must use the Security ID Word-Program
command. To detect end-of-write for the SEC ID, read the toggle bits. Do not use Data# Polling. Once
this is complete, the Sec ID should be locked using the User Sec ID Program Lock-Out. This disables
any future corruption of this space. Note that regardless of whether or not the Sec ID is locked, neither
Sec ID segment can be erased.
The Secure ID space can be queried by executing a three-byte command sequence with Enter Sec ID
command (88H) at address 5555H in the last byte sequence. To exit this mode, the Exit Sec ID com-
mand should be executed. Refer to Table 6 for more details.
Table 4: Product Identification
Address Data
Manufacturer’s ID 0000H BFH
Device ID
SST39VF1601 0001H 234BH
SST39VF1602 0001H 234AH
SST39VF3201 0001H 235BH
SST39VF3202 0001H 235AH
T4.2 25028
©2011 Silicon Storage Technology, Inc. DS25028A 08/11
11
16 Mbit / 32 Mbit Multi-Purpose Flash Plus
SST39VF1601 / SST39VF3201
SST39VF1602 / SST39VF3202
Not Recommended for New Designs
A
Microchip Technology Company
Operations
Table 5: Operation Modes Selection
Mode CE# OE# WE# DQ Address
Read V
IL
V
IL
V
IH
D
OUT
A
IN
Program V
IL
V
IH
V
IL
D
IN
A
IN
Erase V
IL
V
IH
V
IL
X
1
1. X can be V
IL
or V
IH
, but no other value.
Sector or block address,
XXH for Chip-Erase
Standby V
IH
X X High Z X
Write Inhibit X V
IL
X High Z/ D
OUT
X
XXV
IH
High Z/ D
OUT
X
Product Identification
Software Mode V
IL
V
IL
V
IH
See Table 6
T5.0 25028
Table 6: Software Command Sequence
Command
Sequence
1st Bus
Write Cycle
2nd Bus
Write Cycle
3rd Bus
Write Cycle
4th Bus
Write Cycle
5th Bus
Write Cycle
6th Bus
Write Cycle
Addr
1
1. Address format A
14
-A
0
(Hex).
Addresses A
15
-A
19
can be V
IL
or V
IH
, but no other value, for Command sequence for SST39VF1601/1602,
Addresses A
15
-A
20
can be V
IL
or V
IH
, but no other value, for Command sequence for SST39VF3201/3202,
Data
2
Addr
1
Data
2
Addr
1
Data
2
Addr
1
Data
2
Addr
1
Data
2
Addr
1
Data
2
Word-Program
5555H AAH
2AAAH
55H 5555H A0H WA
3
Data
Sector-Erase
5555H AAH
2AAAH
55H 5555H 80H 5555
H
AAH
2AAAH
55H SA
X
4
30H
Block-Erase
5555H AAH
2AAAH
55H 5555H 80H 5555
H
AAH
2AAAH
55H BA
X
4
50H
Chip-Erase
5555H AAH
2AAAH
55H 5555H 80H 5555
H
AAH
2AAAH
55H 5555
H
10H
Erase-Suspend
XXXX
H
B0H
Erase-Resume
XXXX
H
30H
Query Sec ID
5
5555H AAH
2AAAH
55H 5555H 88H
User Security ID
Word-Program
5555H AAH
2AAAH
55H 5555H A5H WA
6
Data
User Security ID
Program Lock-Out
5555H AAH
2AAAH
55H 5555H 85H XXH
6
0000
H
Software ID
Entry
7,8
5555H AAH
2AAAH
55H 5555H 90H
CFI Query Entry
5555H AAH
2AAAH
55H 5555H 98H
Software ID
Exit
9,10
/CFI Exit/
Sec ID Exit
5555H AAH
2AAAH
55H 5555H F0H
Software ID
Exit
9,10
/CFI Exit/Sec ID
Exit
XXH F0H
T6.6 25028
©2011 Silicon Storage Technology, Inc. DS25028A 08/11
12
16 Mbit / 32 Mbit Multi-Purpose Flash Plus
SST39VF1601 / SST39VF3201
SST39VF1602 / SST39VF3202
Not Recommended for New Designs
A
Microchip Technology Company
2. DQ
15
-DQ
8
can be V
IL
or V
IH
, but no other value, for Command sequence
3. WA = Program Word address
4. SA
X
for Sector-Erase; uses A
MS
-A
11
address lines
BA
X
, for Block-Erase; uses A
MS
-A
15
address lines
A
MS
= Most significant address
A
MS
=A
19
for SST39VF1601/1602 and A
20
for SST39VF3201/3202
5. With A
MS
-A
4
= 0; Sec ID is read with A
3
-A
0
,
SST ID is read with A
3
= 0 (Address range = 000000H to 000007H),
User ID is read with A
3
= 1 (Address range = 000010H to 000017H).
Lock Status is read with A
7
-A
0
= 0000FFH. Unlocked: DQ
3
= 1 / Locked: DQ
3
=0.
6. Valid Word-Addresses for Sec ID are from 000000H-000007H and 000010H-000017H.
7. The device does not remain in Software Product ID Mode if powered down.
8. With A
MS
-A
1
=0; SST Manufacturer ID = 00BFH, is read with A
0
=0,
SST39VF1601 Device ID = 234BH, is read with A
0
=1,
SST39VF1602 Device ID = 234AH, is read with A
0
=1,
SST39VF3201 Device ID = 235BH, is read with A
0
=1,
SST39VF3202 Device ID = 235AH, is read with A
0
=1,
A
MS
= Most significant address
A
MS
=A
19
for SST39VF1601/1602 and A
20
for SST39VF3201/3202
9. Both Software ID Exit operations are equivalent
10. If users never lock after programming, Sec ID can be programmed over the previously unprogrammed bits (data=1)
using the Sec ID mode again (the programmed “0” bits cannot be reversed to “1”). Valid Word-Addresses for Sec ID are
from 000000H-000007H and 000010H-000017H.
Table 7: CFI Query Identification String
1
for SST39VF160x/320x
1. Refer to CFI publication 100 for more details.
Address Data Data
10H 0051H Query Unique ASCII string “QRY”
11H 0052H
12H 0059H
13H 0001H Primary OEM command set
14H 0007H
15H 0000H Address for Primary Extended Table
16H 0000H
17H 0000H Alternate OEM command set (00H = none exists)
18H 0000H
19H 0000H Address for Alternate OEM extended Table (00H = none exits)
1AH 0000H
T7.1 25028

SST39VF3201-70-4C-B3KE-T

Mfr. #:
Manufacturer:
Microchip Technology
Description:
NOR Flash 32M (2Mx16) 70ns 2.7-3.6V Commercial
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union