THD2C620

© 2016 Littelfuse Protection Relays & Controls
Time Delay Relays
Dedicated - Interval
www.littelfuse.com/thd2
Rev: 1-A-061016
THD2 SERIES
Description
The THD2 Series combines accurate timing circuitry with high
power solid-state switching. It can switch motors, lamps,
and heaters directly without a contactor. You can reduce labor,
component cost, and increase reliability with these small,
easy-to-use, Digi-Power timers.
Operation (Interval)
Upon application of input voltage, the time delay begins. The
output energizes during the time delay. At the end of the time
delay, the output de-energizes and remains de-energized until
input voltage is removed.
Reset: Removing input voltage resets the time delay and
the output.
Features & Benefits
FEATURES BENEFITS
Microcontroller based
Repeat Accuracy + / - 0.5%,
Factory calibration + / - 1%
High load currents up
to 20A, 200A inrush
Allows direct control of motors, lamps and heaters
without a contactor
Totally solid state
and encapsulated
No moving parts to arc and wear out over time and
encapsulated to protect against shock, vibration,
and humidity
Metalized
mounting surface
Facilitates heat transfer in high current applications
Compact, low
cost design
Allows flexibility for OEM applications and reduces
labor and components costs
Accessories
P1004-95, P1004-95-X Versa-Pot
Panel mountable, industrial potentiometer
recommended for remote time delay adjustment.
P0700-7 Versa-Knob
Designed for 0.25 in (6.35 mm) shaft of
Versa-Pot. Semi-gloss industrial black finish.
P1015-13 (AWG 10/12), P1015-64 (AWG 14/16)
Female Quick Connect
These 0.25 in. (6.35 mm) female terminals are
constructed with an insulator barrel to provide
strain relief.
P1015-18 Quick Connect to Screw Adapter
Screw adapter terminal designed for use with
all modules with 0.25 in. (6.35 mm) male quick
connect terminals.
Wiring Diagram
L1 N/L2
V = Voltage
L = Load
S1 = Optional Low Current
Initiate Switch
R
T
is used when external
adjustment is ordered.
Ordering Information
MODEL
OUTPUT
RATING
INPUT
VOLTAGE
ADJUSTMENT TIME DELAY
THD2C420 20A 120VAC External 0.1 - 10s
THD2C423 20A 120VAC External 0.1 - 10m
THD2C433 20A 120VAC Onboard 0.1 - 10m
THD2C620 20A 230VAC External 0.1 - 10s
THD2C633 20A 230VAC Onboard 0.1 - 10m
If you don’t find the part you need, call us for a custom product 800-843-8848
© 2016 Littelfuse Protection Relays & Controls
Time Delay Relays
Dedicated - Interval
www.littelfuse.com/thd2
Rev: 1-A-061016
External Resistance vs. Time Delay
This chart applies to externally adjustable part numbers.
The time delay is adjustable over the time delay range selected by varying
the resistance across the
R
T
terminals; as the resistance increases the tie
delay increases.
W
hen selecting an external R
T
, add the tolerances of the timer and the R
T
for the full time range adjustment
.
Examples:
1 to 50 S adjustable time delay, select time delay range 1 and
a 50 K ohn
R
T
. For 1 to 100 S use a 100 K ohm R
T
.
Function Diagram
INTERVAL (IMPULSE-ON)
V = Voltage
NO = Normally
Open Contact
NC = Normally
Closed Contact
TD = Time Delay
R = Reset
= Undefined
Time
THD2 SERIES
Specifications
Time Delay
Range 0.1s - 1000m in 6 adjustable ranges or fixed
Repeat Accuracy ±0.5% or 20ms, whichever is greater
Tolerance
(Factory Calibration) ±1%
Reset Time 150ms
Time Delay vs Temp.
& Voltage ≤ ±2%
Input
Voltage 24, 120, or 230VAC
Tolerance ±20%
AC Line Frequency 50/60 Hz
Output
Type Solid state
Form NO, closed during timing
Maximum Load Current Output Steady State Inrush**
A 6A 60A
B 10A 100A
C 20A 200A
Minimum Load Current 100mA
Voltage Drop 2.5V at rated current
OFF State Leakage Current 5mA @ 230VAC
Protection
Circuitry Encapsulated
Dielectric Breakdown ≥ 2000V RMS terminals to mounting surface
Insulation Resistance ≥ 100 MΩ
Mechanical
Mounting ** Surface mount with one #10 (M5 x 0.8) screw
Dimensions H 50.8 mm (2); W 50.8 mm (2”);
D 38.4 mm (1.51”)
Termination 0.25 in. (6.35 mm) male quick connect terminals
Environmental
Operating/Storage
Temperature -40° to 60°C / -40° to 8C
Humidity 95% relative, non-condensing
Weight 3.9 oz (111 g)
**Must be bolted to a metal surface using the included heat sink compound. The maximum
mounting surface temperature is 90°C. Inrush: Non-repetitive for 16ms.

THD2C620

Mfr. #:
Manufacturer:
Littelfuse
Description:
Time Delay & Timing Relays TIMER-INTERVAL
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet