4
Insulation and Safety Related Specifications
Parameter Symbol Value Units Conditions
Minimum External Air Gap
(External Clearance)
L(101) 5 mm Measured from input terminals to output terminals,
shortest distance through air.
Minimum External
Tracking (External Creepage)
L(102) 5 mm Measured from input terminals to output terminals,
shortest distance path along body.
Minimum Internal Plastic Gap
(Internal Clearance)
0.08 mm Through insulation distance conductor to conductor,
usually the straight line distance thickness between
the emitter and detector.
Tracking Resistance
(Comparative Tracking Index)
CTI 175 V DIN IEC 112/VDE 0303 Part 1
Isolation Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1)
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics* (Option 060)
Description Symbol Characteristic Unit
Installation classification per DIN VDE 0110/39, Table 1
for rated mains voltage
d 150 Vrms
for rated mains voltage
d 300 Vrms
I – IV
I – III
Climatic Classification 55/85/21
Pollution Degree (DIN VDE 0110/1.89) 2
Maximum Working Insulation Voltage V
IORM
560 Vpeak
Input to Output Test Voltage, Method b*
V
IORM
x 1.875=V
PR
, 100% Production Test with tm=1 sec,
Partial discharge < 5 pC
V
PR
1050 Vpeak
Input to Output Test Voltage, Method a*
V
IORM
x 1.5=V
PR
, Type and Sample Test, tm=60 sec,
Partial discharge < 5 pC
V
PR
840 Vpeak
Highest Allowable Overvoltage
(Transient Overvoltage t
ini
=10 sec)
V
IOTM
6000 Vpeak
Safety-limiting values – maximum values allowed in the event
of a failure.
Case Temperature
Input Current**
Output Power**
T
S
I
S, INPUT
P
S, OUTPUT
150
150
600
°C
mA
mW
Insulation Resistance at T
S
, V
IO
= 500 V R
S
>10
9
:
* Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog, under Product Safety Regulations section, (IEC/
EN/DIN EN 60747-5-2) for a detailed description of Method a and Method b partial discharge test profiles.
** Refer to the following figure for dependence of P
S
and I
S
on ambient temperature.
Recommended Operating Conditions
Parameter Symbol Min. Max. Units
Input Current, Low Level I
FL
* 0 250 μA
Input Current, High Level I
FH
** 5 15 mA
Supply Voltage, Output V
CC
4.5 5.5 V
Fan Out (R
L
= 1 kΩ) N 5 TTL Loads
Output Pull-Up Resistor R
L
330 4,000 Ω
Operating Temperature T
A
-40 85 °C
* The off condition can also be guaranteed by ensuring that V
F
(off) ≤ 0.8 volts.
** The initial switching threshold is 5mA or less. It is recommended that 6.3mA to 10mA be used for best performance and to permit at least a
20% LED degradation guardband.