Protected Quad Driver
with Fault Detection and Sleep Mode
A2557
5
Allegro MicroSystems, Inc.
115 Northeast Cutoff
Worcester, Massachusetts 01615-0036 U.S.A.
1.508.853.5000; www.allegromicro.com
Limits
Characteristic Symbol Test Conditions Min. Typ. Max. Units
Output Leakage Current* I
CEX
V
O
= 60 V, V
I
= 0.8 V, V
OE
= 2.0 V — 30 100 μA
V
O
= 60 V, V
I
= 2.0 V, V
OE
= 0.8 V — <1.0 100 μA
Output Sustaining Voltage V
O(SUS)
I
O
= 100 mA, V
I
= V
OE
= 0.8 V, V
CC
= Open 40 — — V
Output Saturation Voltage V
O(SAT)
I
O
= 100 mA — 65 200 mV
I
O
= 300 mA — 180 300 mV
Over-Current Limit I
OM
5 ms PulseTest, V
O
= 5.0 V — 500 — mA
Input Voltage V
IH
IN
n
or ENABLE 2.0 — — V
V
IL
IN
n
or ENABLE
— — 0.8 V
Input Current I
IH
IN
n
or ENABLE, V
IH
= 2.0 V — — 10 μA
I
IL
IN
n
or ENABLE, V
IL
= 0.8 V — — -10 μA
Fault Output Leakage Current I
FLT
V
FLT
= 60 V — 4.0 15 μA
V
FLT
= 5 V — <1.0 2.0 μA
Fault Output Current I
FLT
V
FLT
=
5 V, Driver Output Open,
V
I
= 0.8 V, V
OE
= 2.0 V 40 60 80 μA
Fault Output Saturation Voltage V
FLT(SAT)
I
FLT
= 30 μA — 0.1 0.4 V
Clamp Diode Forward Voltage V
F
I
F
= 500 mA — 1.2 1.7 V
I
F
= 750 mA — 1.5 2.1 V
Clamp Diode Leakage Current I
R
V
R
= 60 V — — 50 μA
Turn-On Delay t
PHL
I
O
= 300 mA, 50% V
I
to 50% V
O
— 0.6 10 μs
From Sleep, I
O
= 300 mA, 50% V
I
to 50% V
O
— 3.0 — μs
I
O
= 300 mA, 50% V
OE
to 50% V
O
— 1.3 10 μs
Turn-Off Delay t
PLH
I
O
= 300 mA, 50% V
I
to 50% V
O
— 2.0 10 μs
I
O
= 300 mA, 50% V
OE
to 50% V
O
— 1.4 10 μs
Total Supply Current I
CC
All Outputs Off — 0.075 0.1 mA
Any One Output On — 12 20 mA
Two Outputs On — 18 30 mA
Three Outputs On — 24 40 mA
All Outputs On — 30 50 mA
Thermal Limit T
J
— 165 — °C
ELECTRICAL CHARACTERISTICS over operating temperature range, V
CC
= 4.75 V to 5.25 V
Typical Data is at T
A
= +25°C and V
CC
= 5 V and is for design information only.
Negative current is defi ned as coming out of (sourcing) the specifi ed terminal.
As used here, -100 is defi ned as greater than +10 (absolute magnitude convention) and the minimum is implicitly zero.
* Measurement includes output fault-sensing pull-down current.