6
Device
Series Parameter Symbol Min. Typ. Max. Units Test Conditions
2200 7000 µcd I
F
= 100 mA Peak:
Luminous Intensity/Segment
[1,2]
I
V
1 of 5 df
(Digit Average)
3400 µcd I
F
= 20 mA
Forward Voltage/Segment or DP V
F
2.6 3.5 V I
F
= 100 mA
HDSP-
420X Peak Wavelength λ
PEAK
583 nm
Dominant Wavelength
[3,6]
λ
d
581.5 586 592.5 nm
Reverse Voltage/Segment or DP
[4]
V
R
3.0 25.0 V I
R
= 100 µA
Temperature Coefficient of ∆V
F
/°C -2 mV/°C
V
F
/Segment or DP
Thermal Resistance LED Junction- Rθ
J-PIN
375 °C/W/
to-Pin Seg
Device
Series Parameter Symbol Min. Typ. Max. Units Test Conditions
680 1500 µcd I
F
= 10 mA
Luminous Intensity/Segment
[1,2]
I
V
(Digit Average)` 1960 µcd I
F
= 50 mA Peak:
1 of 5 df
Forward Voltage/Segment or DP V
F
2.1 2.5 V I
F
= 10 mA
HDSP- Peak Wavelength λ
PEAK
566 nm
860X
Dominant Wavelength
[3,6]
λ
d
571 577 nm
Reverse Voltage/Segment or DP
[4]
V
R
3.0 50.0 V I
R
= 100 µA
Temperature Coefficient of ∆V
F
/°C -2 mV/°C
V
F
/Segment or DP
Thermal Resistance LED Junction- Rθ
J-PIN
375 °C/W/
to-Pin Seg
Green
Notes:
1. Case temperature of the device immediately prior to the intensity measurement is 25°C.
2. The digits are categorized for luminous intensity. The intensity category is designated by a letter on the side of the package.
3. The dominant wavelength, λ
d
, is derived from the CIE chromaticity diagram and is that single wavelength which defines the color of
the device.
4. Typical specification for reference only. Do not exceed absolute maximum ratings.
5. For low current operation, the AlGaAs Red HDSP-N100 series displays are recommended. They are tested at 1 mA dc/segment and
are pin for pin compatible with the HDSP-N150 series.
6. The Yellow (HDSP-4200) and Green (HDSP-8600) displays are categorized for dominant wavelength. The category is designated by
a number adjacent to the luminous intensity category letter.
Yellow