5 www.fairchildsemi.com
74AC399 • 74ACT399
AC Operating Requirements for AC
Note 8: Voltage Range 5.0 is 5.0V ± 0.5V
AC Electrical Characteristics for ACT
Note 9: Voltage Range 5.0 is 5.0V ± 0.5V
AC Operating Requirements for ACT
Note 10: Voltage Range 5.0 is 5.0V ± 0.5V
Capacitance
V
CC
T
A
= +25°CT
A
= −40°C to +85°C
Symbol Parameter (V)
C
L
= 50 pF C
L
= 50 pF
Units
(Note 8) Typ Guaranteed Minimum
t
S
Setup Time, HIGH or LOW 3.3 2.0 4.0 4.0
ns
I
n
to CP 5.0 1.5 3.0 3.0
t
H
Hold Time, HIGH or LOW 3.3 0.5 1.0 1.0
ns
I
n
to CP 5.0 0.5 1.0 1.0
t
S
Setup Time, HIGH or LOW 3.3 3.5 5.5 5.5
ns
S to CP 5.0 2.0 4.0 4.0
t
H
Hold Time, HIGH or LOW 3.3 0.5 1.0 1.0
ns
S to CP 5.0 0.5 1.0 1.0
t
W
CP Pulse Width, 3.3 3.0 4.5 4.5
ns
HIGH or LOW 5.0 2.0 3.5 3.5
V
CC
T
A
= +25°CT
A
= −40°C to +85°C
Symbol Parameter
(V)
V
CC
= +5.0V V
CC
= 5.0V
Units
(Note 9)
C
L
= 50 pF C
L
= 50pF
Min Typ Max Min Max
f
MAX
Input Clock Frequency 5.0 165 180 160 MHz
t
PLH
Propagation Delay
5.0 1.5 7.0 8.0 1.5 8.5 ns
CP to Q
t
PHL
Propagation Delay
5.0 2.0 6.0 9.0 2.0 9.5 ns
CP to Q
V
CC
T
A
= +25°CT
A
= −40°C to +85°C
Symbol Parameter (V)
C
L
= 50 pF C
L
= 50 pF
Units
(Note 10) Typ Guaranteed Minimum
t
S
Setup Time, HIGH or LOW 5.0 0.8 2.5 2.5 ns
I
n
to CP
t
H
Hold Time, HIGH or LOW 5.0 0 1.0 1.0 ns
I
n
to CP
t
S
Setup Time, HIGH or LOW 5.0 0.8 4.0 4.0 ns
S to CP
t
H
Hold Time, HIGH or LOW 5.0 −1.0 0.5 0.5 ns
S to CP
t
W
CP Pulse Width, 5.0 1.7 3.5 3.5 ns
HIGH or LOW
Symbol Parameter Typ Units Conditions
C
IN
Input Capacitance 4.5 pF V
CC
= OPEN
C
PD
Power Dissipation Capacitance 30 pF V
CC
= 5.0V