MC100EP210S
http://onsemi.com
4
Table 4. DC CHARACTERISTICS V
CC
= 2.5 V, V
EE
= 0 V (Note 2)
−40°C 25°C 85°C
Symbol Characteristic Min Typ Max Min Typ Max Min Typ Max Unit
I
EE
Power Supply Current 150 200 150 200 150 200 mA
V
OH
Output HIGH Voltage (Note 3) 1250 1400 1550 1250 1400 1550 1250 1400 1550 mV
V
OL
Output LOW Voltage (Note 3) 800 950 1100 800 950 1100 800 950 1100 mV
V
IHCMR
Input HIGH Voltage Common Mode
Range (Differential Configuration)
(Note 4)
1.2 2.5 1.2 2.5 1.2 2.5 V
R
T
Internal Termination Resistor 43 57 43 50 57 43 57
W
I
IH
Input HIGH Current 150 150 150
mA
I
IL
Input LOW Current CLK
CLK
−150
−150
150
150
−150
−150
150
150
−150
−150
150
150
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
2. Input and output parameters vary 1:1 with V
CC
.
3. All loading with 100 W across LVDS differential outputs.
4. V
IHCMR
min varies 1:1 with V
EE
, V
IHCMR
max varies 1:1 with V
CC
. The V
IHCMR
range is referenced to the most positive side of the differential
input signal.
Table 5. AC CHARACTERISTICS V
CC
= 2.375 to 2.625 V, V
EE
= 0 V (Note 5)
−40°C 25°C 85°C
Symbol Characteristic Min Typ Max Min Typ Max Min Typ Max Unit
f
maxLVDS/
LVPECL
Maximum Frequency
(See Figure 2. F
max
/JITTER)
> 1 > 1 > 1 GHz
t
PLH
t
PHL
Propagation Delay 425 525 625 450 550 650 475 575 675 ps
t
skew
Within−Device Skew (Note 6)
Device−to−Device Skew (Note 7)
Duty Cycle Skew (Note 8)
20
85
80
25
160
100
20
85
80
25
160
100
20
85
80
35
160
100
ps
t
JITTER
RMS Random Clock Jitter 0.2 < 1 0.2 < 1 0.2 < 1 ps
V
PP
Minimum Input Swing 150 800 1200 150 800 1200 150 800 1200 mV
t
r
/t
f
Output Rise/Fall Time (20%−80%) 50 130 200 75 150 225 80 160 230 ps
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
5. Measured with 400 mV source, 50% duty cycle clock source. All loading with 100 W across differential outputs.
6. Skew is measured between outputs under identical transitions of similar paths through a device.
7. Device−to−Device skew for identical transitions at identical V
CC
levels.
8. Duty cycle skew guaranteed only for differential operation measured from the cross point of the input to the cross point of the output.