B88069X6420C102

Surge arrester
2-electrode arrester
Series/Type: M51-A900X
Ordering code: B88069X6420C102
Version/Date: Issue 02 / 2006-05-16
Version: 01
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the
table and then change the color to "white" (or invisible). This ensures that the table disappears for the customer
PDF. To update the data sheet, click on the symbol "Preview" and then "Close". Please do not alter the header or
footer when copying the content.
Identification/Classification 1:
(header 1 + top left header bar)
Surge arrester
Identification/Classification 2:
(header 2 + bottom left header bar)
2-electrode arrester
Ordering code:
(top right header bar)
B88069X6420C102
Series/Type:
(top right header bar)
M51-A900X
EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
EPCOS AG is a TDK Group Company.
Surge arrester B88069X6420C102
2-electrode arrester M51-A900X
KB AB E / KB AB PM Issue 02 / 2006-05-16
Please read Cautions and warnings and Page 2 of 4
Important notes at the end of this document.
Features Applications
Very small size
High current rating
Fast response time
Stable performance over life
Very low capacitance
High insulation resistance
RoHS-compatible
Branch exchange (MDF)
Subscriber protection
Line protection
Consumer electronics
Alarm systems
Electrical specifications
DC spark-over voltage
1) 2)
900
± 20
V
%
Impulse spark-over voltage
at 100 V/µs - for 99 % of measured values
- typical values of distribution
at 1 kV/µs - for 99 % of measured values
- typical values of distribution
< 1700
< 1450
< 1850
< 1600
V
V
V
V
Service life
10 operations 50 Hz, 1 s 2.5 A
1 operation 50 Hz, 0.18 s (9 cycles) 5.0 A
10 operations 8/20 µs
2.5 kA
1 operation 8/20 µs
5.0 kA
1 operation 10/350 µs
3)
0.5 kA
Insulation resistance at 100 V
dc
> 1
GΩ
Capacitance at 1 MHz < 1 pF
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
~ 10
~ 0.5
~ 60
V
A
V
Weight ~ 1 g
Operation and storage temperature -40 ... +90 °C
Climatic category (IEC 60068-1) 40/ 90/ 21
Marking, blue negative
900 YY O
900 - Nominal voltage
YY - Year of production
O - Non radioactive
1)
At delivery AQL 0.65 level II, DIN ISO 2859
2)
In ionized mode
3)
After load: DC spark-over voltage ± 50 %
Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845
Surge arrester B88069X6420C102
2-electrode arrester M51-A900X
KB AB E / KB AB PM Issue 02 / 2006-05-16
Please read Cautions and warnings and Page 3 of 4
Important notes at the end of this document.
Dimensional drawing
Cautions and warnings
Surge arresters must not be operated directly in power supply networks.
Surge arresters may become hot in case of longer periods of current stress (danger of burning).
Surge arresters may be used only within their specified values. In case of overload, the lead
contacts may fail or the component may be destroyed.
Damaged surge arresters must not be re-used.
Not to scale
Dimensions in mm
Non controlled document

B88069X6420C102

Mfr. #:
Manufacturer:
EPCOS / TDK
Description:
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors M51-A900X