MI-A66-MU-S

MI-IAM Rev 1.5 vicorpower.com
Page 4 of 6 03/2017 800 927.9474
MI-IAM™
VOLTS-PEAK VALUE OF SPIKE VOLTAGE
TIME (SECONDS)
1s
0
10
100ms
-1
10
10ms
-2
10
1ms
-3
10
-4
10
-5
10
-6
10
600
400
200
0
200
400
600
800
Ratings Exceeded
500V
OVP
MI-IAM Safe Operating Area, 270Vin
400V
VOLTS-PEAK VALUE OF SPIKE VOLTAGE
TIME (SECONDS)
1s
0
10
100ms
-1
10
10ms
-2
10
1ms
-3
10
-4
10
-5
10
-6
10
-600
-500
-400
-300
-200
-100
0
100
200
300
400
500
600
Ratings Exceeded
50V
MI-IAM Safe Operating Area, 28Vin
OVP
28V
DC
Input 270V
DC
Input
Safe Operating Area
[a]
Typical Connection Diagram
MI-IAM
Gate Out
Parallel
Gate In
+OUT
-OUT
-In
-In
+In
+In
+
+IN
Gate IN
Gate OUT
-IN
MI-Converter
C1
4700pF
4700pF
Input Voltage Range Capacitance (C1)
28V
DC
(18.8-50V) 390μF (Max.)
270V
DC
(125-400V) 27μF (Max.)
Parameter Qualification
Altitude
MIL-STD-810D, Method 500.2, Procedure III, explosive decompression (40K ft.).
MIL-STD-810D, Method 500.2, Procedure II, 40,000ft., 1000 – 1500ft./ min. to 70,000ft., unit functioning
Explosive Atmosphere MIL-STD-810C, Method 511.1, Procedure I
Vibration
MIL-STD-810D, Method 514.3, Procedure I, category 6, helicopter, 20g
MIL-STD-810D, Method 514.3 random: 10 – 300Hz @ 0.02g
2
/Hz, 2000Hz @ 0.002g
2
/ Hz, 3.9 total Grms
3h rs/axis. Sine: 30Hz @ 20g, 60Hz @ 10g, 90Hz @ 6.6g, 120Hz @ 5.0g, 16.0 total Grms, 3 axes
MIL-STD-810E, Method 514.4, Table 514.4-VII, ±6db/octave, 7.7Grms, 1hr/axis
Shock
MIL-STD-810D, Method 516.3, Procedure I, functional shock, 40g
MIL-STD-202F, Method 213B, 18 pulses, 60g, 9msec
MIL-STD-202F, Method 213B, 75g, 11ms saw tooth shock
MIL-STD-202F, Method 207A, 3 impacts / axis, 1, 3, 5 feet
Acceleration MIL-STD-810D, Method 513.3, Procedure II Operational test, 9g for 1 minute along 3 mutually perpendicular axes
Humidity MIL-STD-810D, Method 507.2, Procedure I, cycle I, 240 hrs, 88% relative humidity
Solder Test MIL-STD-202, Method 208, 8hr. aging
Fungus MIL-STD-810C, Method 508.1
Salt-Fog MIL-STD-810C, Method 509.1
ENVIRONMENTAL QUALIFICATIONS
[a]
Refer to Input Characteristics
10V
U2
U1
OC
OV
V
REF
2
V
REF
1
+OUT
–OUT
Level
Shift
–IN
+IN
–IN
+IN
GATE IN
GATE OUT
PARALLEL
Q1
Q2
EMI Filter
D1
D2
C2
Specifications (Cont.)
MI-IAM Rev 1.5 vicorpower.com
Page 5 of 6 03/2017 800 927.9474
MI-IAM™
5
6
7
8
9
4
3
2
1
0.080 Dia (2) places
Standard
Solder plate
over copper alloy
0.040 (1,0) Dia (7) places
Standard
Solder plate
over copper alloy
.01
Aluminum Base
Product ID
this surface
Function
+IN
–IN
+OUT
Parallel
Gate OUT
–OUT
Pin #
1
2
3
4
5
6
7
8
9
FULL R
+0.030 (0,76)
-0.000 (0)
(5,6) Min.
(7,6) Min.
(44,4) Max.
2.40
2.28
0.12
0.50
1.90
0.65
(16,5)
0.49
(12,4)
0.30±.015
(7,6)±(0,38)
0.15
2.10
(53,4)
1.30
0.40
(10,2)
0.35± 0.015
(8,9)±(0,38)
1.40
(35,6)
1.00
(25,4)
0.70
(17,8)
+IN
–IN
Gate IN
MI-IAM
(57,9)
(33,0)
(3,8)
0.15
(3,8)
(48,3)
0.22
(3,0)
(12,7)
0.30
(61,0)
1.75
MI-IAM
Note: For alternate packaging options refer to the mechanical drawing page of vicorpower.com
Mechanical Drawing
[1]
EMI performance is subject to a wide variety of external influences such as PCB construction, circuit layout etc. As such, external components in addition to
those listed herein may be required in specific instances to gain full compliance to the standards specified.
MI-IAM Rev 1.5 vicorpower.com
Page 6 of 6 03/2017 800 927.9474
MI-IAM™
Vicor’s comprehensive line of power solutions includes high density AC-DC and DC-DC modules and
accessory components, fully configurable AC-DC and DC-DC power supplies, and complete custom
power systems.
Information furnished by Vicor is believed to be accurate and reliable. However, no responsibility is assumed by Vicor for its use. Vicor
makes no representations or warranties with respect to the accuracy or completeness of the contents of this publication. Vicor reserves
the right to make changes to any products, specifications, and product descriptions at any time without notice. Information published by
Vicor has been checked and is believed to be accurate at the time it was printed; however, Vicor assumes no responsibility for inaccuracies.
Testing and other quality controls are used to the extent Vicor deems necessary to support Vicor’s product warranty. Except where
mandated by government requirements, testing of all parameters of each product is not necessarily performed.
Specifications are subject to change without notice.
Vicor’s Standard Terms and Conditions and Product Warranty
All sales are subject to Vicor’s Standard Terms and Conditions of Sale, and Product Warranty which are available on Vicor’s webpage
(http://www.vicorpower.com/termsconditionswarranty) or upon request.
Life Support Policy
VICOR’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE
EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF VICOR CORPORATION. As used
herein, life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and
whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to
result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform
can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. Per Vicor Terms
and Conditions of Sale, the user of Vicor products and components in life support applications assumes all risks of such use and indemnifies
Vicor against all liability and damages.
Intellectual Property Notice
Vicor and its subsidiaries own Intellectual Property (including issued U.S. and Foreign Patents and pending patent applications) relating
to the products described in this data sheet. No license, whether express, implied, or arising by estoppel or otherwise, to any intellectual
property rights is granted by this document. Interested parties should contact Vicor’s Intellectual Property Department.
Vicor Corporation
25 Frontage Road
Andover, MA, USA 01810
Tel: 800-735-6200
Fax: 978-475-6715
email
Customer Service:
custserv@vicorpower.com
Technical Support: apps@vicorpower.com

MI-A66-MU-S

Mfr. #:
Manufacturer:
Vicor
Description:
Power Line Filters MIA66MUS (IAM SLIM)