PD-4
REV.: 1/2016 www.recom-power.com
DC/DC Converter
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
RP12-AW
Series
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
UL General Safety E196683
UL60950-1 1st Ed.: 2003
C22.2 No. 60950 1st. Ed.: 2003
EMC Compliance Condition Standard / Criterion
EMI Standard
(8)
with external filter EN55022, Class A or B
ESD
Radiated Immunity
Fast Transient
(9)
Surge
(9)
Conducted Immunity
Air ±8kV and Contact ± 6kV
10 V/m
±2kV
±1kV
10 Vr.m.s
EN61000-4-2, Criteria A
EN61000-4-3, Criteria A
EN61000-4-4, Criteria A
EN61000-4-5, Criteria A
EN61000-4-6, Criteria A
continued on next page
Notes:
Note8: The standard modules meet EMI Class A or Class B with external components, see filter suggestions below.
Note9: An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5. The filter capacitor Recom
suggests: Nippon chemi-con KY series, 220μF/100V.
Notes:
Note6: BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40°C (Ground fixed and
controlled environment).
Note7: Derating graphs are valid only for the shown part numbers. If you need detailed derating-
information about a part number not shown here please contact our technical support
service at techsupportAT@recom-power.com.
-40 60
70
80
100
120
40
200-20
0
20
40
60
80
100
Ambient Temperature [°C]
Output Power [%]
RP12-2415SAW
Derating Graph
(7)
EMC Filtering Class A
Input
DC
DC
Fuse
C1
+V
IN
+V
OUT
-V
OUT
-V
IN
LOAD
C3
C2
DC
DC
Fuse
C1
+V
IN
+V
OUT
COM
-V
OUT
-V
IN
LOADLOAD
C3
Input
DC
DC
Fuse
C1
+V
IN
+V
OUT
-V
OUT
-V
IN
LOAD
C3
C2
DC
DC
Fuse
C1
+V
IN
+V
OUT
COM
-V
OUT
-V
IN
LOADLOAD
C3