Description
The RP12-AW wide range input DC/DC converters are certified to UL 60950-1 and cUL 60950-1.
This makes them ideal for all telecom and industrial applications where approved safety standards
are required. The DIP24 package is available in both pinned and SMD case styles and meets military
standards for thermal shock and vibration tolerance.
E196683
12 Watt
DIP24/SMD
Single & Dual
Output
RP12-AW
Selection Guide
Part Number Input Output Output Input
(1)
Efficiency
(1)
Max. Capacitive
Voltage Range Voltage Current Current typ. Load
(2)
[VDC] [VDC] [mA] [mA] [%] [µF]
RP12-243.3SAW
(3)
9-36 3.3 3500 573 84 2000
RP12-2405SAW
(3)
9-36 5.1 2400 575 87 2000
RP12-2412SAW
(3)
9-36 12 1000 575 87 430
RP12-2415SAW
(3)
9-36 15 800 575 87 300
RP12-483.3SAW
(3)
18-75 3.3 3500 286 84 2000
RP12-4805SAW
(3)
18-75 5.1 2400 293 87 2000
RP12-4812SAW
(3)
18-75 12 1000 287 87 430
RP12-4815SAW
(3)
18-75 15 800 284 88 300
RP12-2405DAW
(3)
9-36 ±5 ±1200 595 84 ±1250
RP12-2412DAW
(3)
9-36 ±12 ±500 575 87 ±200
RP12-2415DAW
(3)
9-36 ±15 ±400 575 87 ±120
RP12-4805DAW
(3)
18-75 ±5 ±1200 294 85 ±1250
RP12-4812DAW
(3)
18-75 ±12 ±500 287 87 ±200
RP12-4815DAW
(3)
18-75 ±15 ±400 287 87 ±120
UL60950-1 Certified
Input Voltage
Output Voltage
Single or Dual
RP12-__ __ _AW/_
Package
(3)
Ordering Examples:
RP12-2412SAW/SMD = 24V Input, 12V Output, Single, SMD Package.
Model Numbering
Notes:
Note1: Maximum value at nominal input voltage and full load.
Note2: Test by minimum Vin and constant resistor load.
Notes:
Note3: no suffix for standard package (DIP24), add suffix „SMD“ for SMD package