45W PWM Output LED Driver
IDLV-45 series
File Name:IDLV-45-SPEC 2018-01-10
IDLV-45 -12
IDLV-45 -24
IDLV-45 -36
IDLV-45 -48 IDLV-45 -60
SPECIFICATION
MODEL
OUTPUT
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT
47 ~ 63Hz
105 ~ 115%
Protection type : Hiccup mode, recovers automatically after fault condition is removed
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 40 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
ENVIRONMENT
SAFETY &
EMC
PROTECTION
EMC IMMUNITY
EMC EMISSION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
TOTAL HARMONIC DISTORTION
I/P-O/P:3.75KVAC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
±10%
0~100%
84%
86%
88%
88% 90%
0.6A / 115VAC 0.4A / 230VAC 0.3A / 277VAC
<0.75mA / 277VAC
120*75*25mm (L*W*H)
0.22Kg;54pcs/13Kg/ 0.93CUFT
SHORT CIRCUIT
Shut down O/P voltage, overe power on to c ry-re
DIMMING RANGE
DC VOLTAGE
RATED POWER
SETUP TIME
Note.3
VOLTAGE TOLERANCE
VOLTAGE RANGE Note.2
1KHz( 20%)±
500ms / 230VAC 1200ms/115VAC
12V
24V
36V
48V 60V
3.0A
1.88A
1.25A
0.94A
36W
45.12W
45W
45.12W
0.75A
45W
PWM FREQUENCY (Typ.)
AUXILIARY DC OUTPUT
Note.4
Nominal 12V(deviation 11.4~12.6)@50mA for A-Type only
(Please refer to "STATIC CHARACTERISTIC" section)
90 ~ 295VAC 127 ~ 417VDC
PF>0.95/115VAC, PF>0.92/230VAC, PF>0.9/277VAC@full load
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
THD< 20%(@load 60%/115VAC,230VAC; @load 75%/277VAC)≧≧
(Please refer to “TOTAL HARMONIC DISTORTION” section)
COLD START 30A(twidth= s measured at 50% Ipeak) at 230VAC150μ;Per NEMA 410
<0.5W for Blank-Type, <1.2W for A-Type
NO LOAD POWER CONSUMPTION
WORKING TEMP.
MAX. CASE TEMP.
Tcase=-20 ~ +85 (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)℃
Tcase=+85℃
Compliance to EN55015, EN61000-3-2 Class C ( ) ; EN61000-3-3,GB17743,GB17625.1, EAC TP TC 020@load 60%≧
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level( ), EAC TP TC 020surge immunity:Line-Line:1KV
1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25 of ambient temperature.℃
2. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
3. Length of set up time is measured at cold first start. Turning ON/OFF the driver may lead to increase of the set up time.
4. Aux. 12V will be damaged with short circuit; It will not be available with dimming off or output no load condition.
5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be
affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC
RATED CURRENT
386.59Khrs min. MIL-HDBK-217F (25 )℃
UL8750,CSA C22.2 NO.250.13-12; EN/AS/NZS 61347-1 & EN/AS/NZS 61347-2-13 independent, EN62384,
GB19510.1, GB19510.14, BIS IS15885(for IDLV-45-12,24,48 only), EAC TP TC 004 approved