AC input range selected by switch
Built-in passive PFC function compliance to EN61000-3-2
With AC ON-OFF switch
3 poles AC inlet with fuse holder
Protections: Short circuit / Overload / Over voltage / Over temperature
Charger type can be selected (Optional)
Charger for lead-acid batteries
2 color LED loading indicator
Open frame models available (Without safety approval)
Low cost, High reliability
2 years warranty
Features :
S:PowerSupply
A:Voltagedetector
:O.D.M.number
P:OpenP.C.B.
C:Withcase
13:13.8V
27:27.6V
54:55.2V
B:Currentdetector
P:WithPFC
N:NonePFC
P A 120 P 13 C
120WSingleOutputPowerSupplyorBatteryCharger
PA/PB-120 series
SPECIFICATION
PA/PB-120 -13
PA/PB-120 -27 PA/PB-120 -54
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
LEDINDICATED
OUTPUT
VOLTAGERANGE
FREQUENCY RANGE
POWERFACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
ENVIRONMENT
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
OVERTEMPERATURE
SAFETY STANDARDS
HARMONICCURRENT
EMICONDUCTION&RADIATION
SAFETY &
EMSIMMUNITY
EMC
(Note4)
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
OVERLOAD
OVERVOLTAGE
PROTECTION
ACCURRENT (Typ.)
13.8V 27.6V 55.2V
7.2A 4.3A 2.2A
0~7.2A 0~4.3A 0~2.2A
99.36W
PA seriesvoltage105% 1% :RED/105%
1% :GREEN
PBseriesload46% 10% :GREEN/46%
10% :RED
118.68W 121.44W
88~132VAC/176~264VACselectedbyswitch
47~63Hz
>0.65(withPFCseries)
73% 79% 79%
3A/115VAC1.5A/230VAC
COLDSTART 25A/115VAC50A/230VAC
<1.5mA /240VAC
90~110%ratedoutputpower
15~17V 30~35V 60~66V
Protectiontype: Constantcurrentlimiting,recoversautomaticallyafterfaultconditionisremoved
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
RTH2 70 10 detectonRTH2thermistor
Protectiontype:Shutdowno/pvoltage,recoversautomaticallyaftertemperaturegoesdown
UL60950-1, TUVEN60950-1,EN60335,EN60335-1,EN60335-2-29approved
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024,lightindustrylevel,criteria A
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC
-10~+45 (Refertooutputloadderatingcurve)
20~90%RHnon-condensing
-20~+85 ,10~95%RH
0.05%/ (0~45
10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes
TUV
Rhe inl and
Pro duc tSafe ty
geprUfre
Sicherheit
MTBF
149.6Khrsmin.MIL-HDBK-217F(25 )
DIMENSIONOTHERS
NOTE
PACKING
PCB Type:144*90*33mmExternalcasetype:180*96*49mm(L*W*H)
1.1Kg;16pcs/17.9Kg/1.47CUFT(withoutPFC)1.24Kg;16pcs/20.1Kg/1.47CUFT(withPFC)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. With PFC I/P range: 95~132VAC/190~264VAC.
6. For open P.C.B. WITH 17.8CFM min. Forced air.
FileName:PA,PB-120-SPEC2008-05-06