4
FN3182.9
July 22, 2013
Output Leakage Currents of
OUT and HYST
I
OLK
V
SET
= 0V or V
SET
≥ 2V - 10 200 nA
I
HLK
- -10 -100 nA
I
OLK
V+ = 15V - - 2000 nA
I
HLK
- - -500 nA
Output Saturation Voltages V
OUT1
V
SET1
= 2V,
I
OUT1
= 2mA
V+ = 2V - 0.2 0.5 V
V+ = 5V - 0.1 0.3 V
V+ = 15V - 0.06 0.2 V
Output Saturation Voltages V
HYST1
V
SET1
= 2V,
I
HYST1
= -0.5mA
V+ = 2V - -0.15 -0.30 V
V+ = 5V - -0.05 -0.15 V
V+ = 15V - -0.02 -0.10 V
Output Saturation Voltages V
OUT2
V
SET2
= 0V,
I
OUT2
= 2mA
V+ = 2V - 0.2 0.5 V
V+ = 5V - 0.15 0.3 V
V+ = 15V - 0.11 0.25 V
Output Saturation Voltages V
HYST2
V
SET2
= 2V V+ = 2V, I
HYST2
= -0.2mA - -0.25 -0.8 V
V+ = 5V, I
HYST2
= -0.5mA - -0.43 -1.0 V
V+ = 15V, I
HYST2
= -0.5mA - -0.35 -0.8 V
V
SET
Input Leakage Current I
SET
GND ≤ V
SET
≤ V+ - 0.01 10 nA
Δ Input for Complete Output
Change
ΔV
SET
R
OUT
= 4.7kΩ,
R
HYST
= 20kΩ,
V
OUT
LO = 1% V+,
V
OUT
HI = 99% V+
ICL7665S - 1.0 - mV
ICL7665SA - 0.1 - mV
Difference in Trip Voltages V
SET1
-
V
SET2
R
OUT
, R
HYST
= 1mW - ±5 ±50 mV
Output/Hysteresis
Difference
R
OUT
, R
HYST
= 1mW ICL7665S - ±1-mV
ICL7665SA - ±0.1 - mV
NOTES:
6. Derate above +25°C ambient temperature at 4mW/°C.
7. All significant improvements over the industry standard ICL7665 are highlighted.
Electrical Specifications The specifications below are applicable to both the ICL7665S and ICL7665SA. V+ = 5V, T
A
= +25°C,
Test Circuit Figure 7. Unless Otherwise Specified (Continued)
PARAMETER SYMBOL TEST CONDITIONS MIN TYP MAX UNITS
ICL7665S