SDR-120-24

SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
PEAK CURRENT
PEAK POWER
Note.6
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.7
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
WORKING TEMP.
DC OK REALY CONTACT RATINGS (max.)
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
1500ms, 60ms/230VAC 3000ms, 60ms/115VAC at full load
20ms/230VAC 20ms/115VAC at full load
88 ~ 264VAC 124 ~ 370VDC
47 ~ 63Hz
89%
0.93/230VAC 0.96/115VAC at full load
1.4A/115VAC 0.7A/230VAC
29 ~ 33V
91%
56 ~ 65V
90.5%
35A/115VAC 70A/230VAC
<1mA / 240VAC
Normally w more than 3 and then shut down o/p voltageorks within 110 ~ 150% rated output power for seconds
14 ~ 17V
>150% rated power, constant current limiting with auto-recovery within 3 seconds and shut down o/p voltage after 3 seconds
Protection type : Shut down o/p voltage, re-power on to recover
95 5 (TSW) detect on heatsink of power switch℃±
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
UL508, TUV EN60950-1 approved
,
;(meet EN60204-1)
EAC TP TC 004
Compliance to EN55011, EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2,-3, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteria A,
EAC TP TC 020, SEMI F47, GL approved
-25 ~ +70 (Refer to "Derating Curve")
60Vdc/0.3A, 30Vdc/1A, 30Vac/0.5A resistive load
20 ~ 95% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
±℃ 0.03%/ (0 ~ 50 )
Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
289.9K hrs min. MIL-HDBK-217F (25 )
40*125.2*113.5mm (W*H*D)
0.67Kg; 20pcs/14.4Kg/1.16CUFT
POWER FACTOR (Typ.)
SDR-120-24 SDR-120-48
24V 48V
5A 2.5A
0 ~ 5A 0 ~ 2.5A
120W 120W
7.5A 3.75A
100mVp-p 120mVp-p
24 ~ 28V 48 ~ 55V
±1.0% ±1.0%
±0.5% ±0.5%
±1.0% ±1.0%
SDR-120-12
12V
10A
0 ~ 10A
120W
15A
180W (3 sec.)
100mVp-p
12 ~ 14V
±1.0%
±0.5%
±1.0%
Features :
SDR-120 series
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25 / 70% RH
ENVIRONMENT
SAFETY &
FUNCTION
EMC
(Note 4)
PROTECTION
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power.
In case the adjacent device is a heat source, 15mm clearance is recommended.
6. 3 seconds max., please refer to peak loading curves.
7. Derating may be needed under low input voltage. Please check the derating curve for more details.
8. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
120W Single Output Industrial DIN RAIL with PFC Function
High efficiency 91% and low power dissipation
150% peak load capability
Built-in active PFC function, PF>0.93
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
UL 508 (industrial control equipment) approved
EN61000-6-2(EN50082-2) industrial immunity level
Built-in DC OK relay contact
100% full load burn-in test
3 years warranty
File Name:SDR-120-SPEC 2018-01-12
EMC IMMUNITY
EMC EMISSION
GL
PQ
S
E
M
I
F
4
7
Bauar
Sicherheit
egel gema
t gepruf t
od
be
www.
ID 2000000000
tuv.com
wac g
os
Mechanical Specification
Block Diagram
Case No.992A Unit:mm
DC OK Relay Contact
DETECTION
PWM & PFC
CIRCUIT
O.L.P.U.V.P.
EMI FILTER
RECTIFIERS
POWER
SWITCHING
FILTER
&
RECTIFIERS
+V
DC OK
-V
I/P
FG
CONTROL
O.V.P.
&
O.C.P.
PFC
CIRCUIT
PFC
CONTROL
Terminal Pin No. Assignment (TB1)
Terminal Pin No. Assignment (TB2)
Pin No.
Pin No.
1
1,2
2
3
4
3
Assignment
Assignment
FG
AC/L
AC/N
DC OUTPUT -V
DC OUTPUT+V
ADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15
35
Relay Contact
1
2
3
125.2
113.5
40
TB1
Contact Close PSU turns on / DC OK.
PSU turns off / DC Fail.
30V/1A resistive load.
Contact Open
Contact Ratings (max.)
SDR-120 series
120W Single Output Industrial DIN RAIL with PFC Function
+
2
3
4
1
TB2
DC OK
DC OK
+V ADJ.
File Name:SDR-120-SPEC 2018-01-12
180W
( 1 ) ( 2 )
120W
100 sec. 3 sec.
180W
60W
15 sec. 3 sec.
-25 0
Continuous
For 3 sec. (typ.)
10 20 30 40 50
55
60 70
60
75
100
125
150
(VERTICAL)
12V
Others
12V
Others
SDR-120 series
120W Single Output Industrial DIN RAIL with PFC Function
INPUT VOLTAGE (V) 60Hz
LOAD (%)
AMBIENT TEMPERATURE ( )
LOAD (%)
100
40
88 110
50
60
70
80
155135 230 264
90
100
Output derating VS input voltageDerating Curve
Peak Loading
File Name:SDR-120-SPEC 2018-01-12

SDR-120-24

Mfr. #:
Manufacturer:
B+B SmartWorx
Description:
DIN Rail Power Supplies POWER SUPPLY, DIN, PFC FUNCTION, 24V, 5A, 120W
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet