AC Power Switch
www.ixysic.com
DS-PM1204-R11
1
Part # Description
PM1204 6-Lead DIP (50/Tube)
PM1204S 6-Lead Surface Mount (50/Tube)
PM1204STR 6-Lead Surface Mount (1000/Reel)
Parameter Rating Units
AC Operating Voltage 120 V
rms
Load Current 500 mA
rms
On-State Voltage Drop
(I
L
=500mA
rms
)
1.4 V
rms
Applications
Features
Description
Ordering Information
Pin Configuration
Programmable Control
Process Control
Power Control Panels
Remote Switching
Gas Pump Electronics
Contactors
Large Relays
Solenoids
Motors
Heaters
Load Current up to 0.5A
rms
Blocking Voltages up to 400V
P
5mA Sensitivity
Zero-Crossing Detection
DC Control, AC Output
Optically Isolated
TTL and CMOS Compatible
Low EMI and RFI Generation
High Noise Immunity
VDE compatible
Machine Insertable, Wave Solderable
The PM1204 is an AC Solid State Switch using optical
coupling with dual power SCR outputs to produce
an alternative to optocoupler and Triac circuits. The
PM1204 switches are robust enough to provide a
blocking voltage of up to 400V
P
. In addition, tightly
controlled zero-cross circuitry ensures switching of
AC loads without the generation of transients. The
input and output circuits are optically coupled to
provide 3750V
rms
of isolation and noise immunity
between control and load circuits. As a result, the
PM1204 is well suited for industrial environments
where electromagnetic interference could disrupt the
operation of electromechanical relays.
Approvals
UL Recognized Component: UL 508 File E69938
CSA Certified Component: File 043639
ZC
1
3
2
4
5
6
AC Load
AC Load
– LED
+ LED
I
NTEGRATED
C
IRCUITS
D
IVISION
www.ixysic.com
2
R11
PM1204
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Absolute Maximum Ratings @ 25ºC
Parameter Min Max Units
Blocking Voltage - 400 V
P
Reverse Input Voltage - 5 V
Input Control Current - 100 mA
Peak (10ms) - 1 A
Input Power Dissipation
1
- 150 mW
Total Package Dissipation
2
- 800 mW
Isolation Voltage, Input to Output 3750 - V
rms
Operational Temperature -40 +85 ºC
Storage Temperature -40 +125 ºC
1
Derate linearly 1.33 mW / ºC
2
Derate linearly 6.67 mW / ºC
Parameter Conditions Symbol Min Typ Max Units
Output Characteristics
AC Operating Voltage I
F
=5mA V
OP
20 - 120 V
rms
Load Current (Continuous) V
L
=120-240VAC I
L
0.005 - 0.5 A
rms
Maximum Surge Current t<16ms I
PEAK
- - 12 A
Off-State Leakage Current V
L
=400V
DC
I
LEAK
--1mA
On-State Voltage Drop I
L
=0.5A
rms
- - - 1.4 V
rms
Critical Rate of Rise - dV/dt 1000 1200 - V/µs
Switching Speeds
Turn-On
I
F
=5mA
t
on
- - 0.5
Cycles
Turn-Off t
off
- - 0.5
Zero-Cross Turn-On Voltage
1
1
st
half-cycle
-
-25V
Subsequent half-cycle - - 1 V
Operating Frequency - - 20 - 500 Hz
Load Power Factor for Guaranteed Turn-On
2
- PF 0.25 - - -
Capacitance Input-To-Output - C
I/O
-3 -pF
Input Characteristics
Input Control Current
For Normal Environment -
I
F
--5
mA
For High Noise Environment - - - 10
Input Voltage Drop I
F
=5mA V
F
0.9 1.2 1.4 V
Input Dropout Voltage - - 0.8 - - V
Reverse Input Current V
R
=5V I
R
- - 10 µA
1
Zero Cross 1
st
half-cycle @ < 100Hz.
2
Snubber circuits may be required at low power factors.
Electrical Characteristics @ 25ºC
I
NTEGRATED
C
IRCUITS
D
IVISION
PM1204
www.ixysic.com
3
R11
PERFORMANCE DATA*
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifi cations, please
contact our application department.
-40
1.2
1.0
0.8
0.6
0.4
0.2
05585
0
Load Current
Free Air
Ambient Temperature (ºC)
Load Current (A
rms
)
R
TJA
= 60ºC/W
20
15
10
5
0
16 50 100
25
Pulse Duration (ms)
Peak Surge Current (A)
Max Surge Current
Non-Repetitive
NOTE: Values apply to
T
J
=50ºC before surge.
0
1.3
1.2
1.1
1.0
10 25 40 55 70 85
0.9
Forward Voltage (V)
Typical Forward Voltage
vs. Temperature
Ambient Temperature (ºC)
0
800
600
400
200
1200
1000
25 50 85
1400
0
Typical dV/dt
vs. Temperature
Ambient Temperature (ºC)
Critical Rate of Rise (V/Ps)
Vo
63%
10%
RC
dV/dt Method
In accordance with
EIA/NARM Standards
RS-443 for Solid State Relays
Vo = 300V
dV
dt
0.63 x 300V
RC
RC
189
==

PM1204S

Mfr. #:
Manufacturer:
IXYS Integrated Circuits
Description:
Triac & SCR Output Optocouplers 400V, 0.5mA AC Power Switch
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet