ASDXL Series
0 in to ±5 in H
2
O, 0 in to 10 in H
2
O, 0 in to ±10 in H
2
O
2 www.honeywell.com/sensing
GENERAL SPECIFICATIONS
Characteristic Parameter Characteristic Parameter
Supply voltage (Vs) 4.75 Vdc to 5.25 Vdc Lead soldering temperature 4 s at 250 °C [482 °F]
Maximum supply voltage 6.50 Vdc max. Vibration 10 g at 20 Hz to 2000 Hz
Current consumption 6 mA typ. Shock 100 g for 11 ms
Output current - sink 2 mA max. Life 1 million cycles min.
Output current - source 2 mA max. Position sensitivity 50 µV/V/g typical
ENVIRONMENTAL SPECIFICATIONS PRESSURE RANGE SPECIFICATIONS
Characteristic Range Listing Pressure Range Burst Pressure
(1)
Compensated 0 °C to 85 °C [32 °F to 185 °F] ASDXL05 0 in to ±5 in H
2
0 3 PSI
Operating -20 °C to 105 °C [-4 °F to 221 °F]
Storage -40 °C to 125 °C [-40 °F to 257 °F]
ASDXL10 0 in to 10 in H
2
0
0 in to ±10 H
2
0
3 PSI
PERFORMANCE CHARACTERISTICS 4D
(2)
Characteristic Min. Typ.(5) Max. Unit
Full scale span (FSS)
(3,4)
– 4.000 – V
Zero pressure offset
(4)
2.400 2.500 2.600 V
Output at full scale pressure (P2)
(4,5)
4.400 4.500 4.600 V
Output at full scale pressure (P1)
(4,5)
0.400 0.500 0.600 V
Accuracy
(6)
– – ±2.5 % FSS
Quantization error
(7)
2.44 – – mV
Response time
(8)
– 8 11 ms
PERFORMANCE CHARACTERISTICS 4R
(2)
Characteristic Min. Typ. Max. Unit
Full scale span (FSS)
(3,4)
– 4.000 – V
Zero pressure offset
(4)
0.400 0.500 0.600 V
Output at full scale pressure
(4)
4.400 4.500 4.600 V
Accuracy
(6,7)
– – ±2.5 % FSS
Quantization error
(7)
2.44 – – mV
Response time
(8)
– 8 11 ms
Notes:
1. If burst pressure is exceeded, even momentarily, the package may leak or the pressure sensing die may fracture.
2. Reference conditions (unless otherwise noted): supply voltage, V
S
=5.0 ±0.01 Vdc, Ta=25 °C [77 °F].
3. Span is the algebraic difference between the output voltage at the specified pressure and the output at zero pressure.
4. Output is ratiometric within the supply voltage range (Vs).
5. Output of the device when maximum positive pressure is applied on the backside (P2) or the front side (P1) of the sensing element.
6. Accuracy is the combined errors from offset and span calibration, linearity, pressure hysteresis, and temperature effects. Calibration errors
include the deviation of offset and full scale from nominal values Linearity is the measured deviation based on a straight line. Hysteresis is the
maximum output difference at any point within the operating pressure range for increasing and decreasing pressure and temperature.
7. Minimum step size in the output due to a change in the input pressure.
8. Response time for 0 PSI to full scale pressure step change, 10% to 90% rise time.
9. 220 nF capacitor required between +Vs and GND.