https://www.phoenixcontact.com/pi/products/1416669
08/18/2018Page2/4
Bus system cable-SAC-5P- 2,0-U40/MINFS-1416669
Technical data
Material
Contact surface material Au
Contact carrier material PVC
Material of grip body PVC
Material, knurls Anodized aluminum
Cable
Cable type DeviceNet trunk cable
Cable abbreviation U40
Cable structure 2xAWG18+2xAWG15+1xAWG18
Conductor cross section 2 x AWG 18 data cable
2 x AWG 15 power supply
1 x AWG 18 drain wire
AWG signal line 18
AWG power supply 15
Conductor structure signal line 19 x AWG 30
Conductor structure, voltage supply 19 x AWG 28
Wire colors Red-black, blue-white
Twisted pairs 2 cores to the pair
Type of pair shielding Plastic-coated aluminum foil, aluminum side outside
Overall twist 2 pairs around a drain wire in the center to the core
Shielding Tinned copper braided shield
Optical shield covering 65 %
External sheath, color gray
External cable diameter D 11.43 mm
Outer sheath, material PVC
Material conductor insulation Foamed PE
PVC (Power supply)
Conductor material Tin-plated Cu litz wires
Flame resistance UL 1581, FT4
Resistance to oil OIL RES I according to UL2256
Other resistance UV resistant (720 h) UL 2556
Ambient temperature (operation) -20 °C ... 75 °C (cable, fixed installation)
-5 °C ... 80 °C (cable, flexible installation)
Standards and Regulations
Flame resistance UL 1581, FT4
Resistance to oil OIL RES I according to UL2256
Other resistance UV resistant (720 h) UL 2556
Environmental Product Compliance
China RoHS Environmentally Friendly Use Period = 50