SPECIFICATION
600W Single Output Switching Power Supply
HEP-600 series
File Name:HEP-600-SPEC 2018-04-26
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
℃
MODEL
DC VOLTAGE
RATED CURRENT
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.5
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
OVER CURRENT
OVER VOLTAGE
OVER TEMPERATURE
Can be adjusted by internal
potentiometer
500ms, 80ms at full load 230VAC /115VAC
15ms at full load 230VAC /115VAC
90 ~ 305VAC 127 ~ 431VDC
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load
7A / 115VAC 3.3A / 230VAC 2.9A / 277VAC
<0.75mA / 277VAC
105 ~ 125%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Compliance to ,EN55032 (CISPR32) Class B, EN61000-3-2,-3 EAC TP TC 020
Compliance to ,
EN61000-4-2,3,4,5,6,8,11, EN55024, heavy industry level EAC TP TC 020
-40 ~ +70 (Refer to "Derating Curve")℃
20 ~ 95% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH non-condensing
℃
±℃ ℃
0.03%/ (0 ~ 60 )
20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1,
EAC TP TC 004 approved
76.9K hrs min. MIL-HDBK-217F (25 )℃
280*144*48.5mm (L*W*H)
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE
Note.3
ENVIRONMENT
SAFETY &
EMC
(
Note.6)
PROTECTION
SHORT CIRCUIT
Constant current limiting, recovers automatically after fault condition is removed
13 ~ 16V 16.5 ~ 20.5V
22 ~ 26V
26 ~ 30V
32.5 ~ 36.5V
39.5 ~ 43.5V 52.5 ~ 56.5V
46 ~ 50V 59 ~ 63V
93%
94%
95%
95%
95.5%
95.5%
96%96% 96%
±3.0%
20 ~ 40A
±2.0%
18 ~ 36A
±1.5%
14 ~ 28A
±1.0%
12.5 ~ 25A
±1.0%
10 ~ 20A
±1.0%
8.3 ~ 16.7A
±1.0%
6.2 ~ 12.5A
±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±0.5%
±0.5%
±2.0%
±1.5% ±1.0% ±0.5% ±0.5%
±0.5%
±0.5%
±1.0%
5.6 ~ 11.2A
±0.5%
±0.5%
±1.0%
7.1 ~ 14.3A
±0.5%
±0.5%
12V
HEP-600-12 HEP-600-15 HEP-600-20 HEP-600-24 HEP-600-30 HEP-600-36 HEP-600-42 HEP-600-48 HEP-600-54
15V 20V 24V 30V
36V
48V
40A 36A 28A 25A
20A
16.7A
12.5A
480W 540W 560W 600W 600W
601.2W
600W
150mVp-p 150mVp-p
12.7 ~ 15.8V
150mVp-p
17 ~ 21V
150mVp-p
20.4 ~ 25.2V
200mVp-p
25.5 ~ 31.5V
250mVp-p
30.6 ~ 37.8V
250mVp-p
40.8 ~ 50.4V10.2 ~ 12.6V
54V
11.2A
604.8W
350mVp-p
45.9 ~ 56.7V
42V
14.3A
600.6W
250mVp-p
35.7 ~ 44.1V
EMC IMMUNITY
EMC EMISSION
COLD START 70A(t =1000 s measured at 50% I ) at 230VAC
width peak
FUNCTION
REMOTE ON/OFF CONTROL
Power on : "Hi" >2 ~ 5V or Open circuit Power off : "Low" <0 ~ 0.5V or Short circuit
5V STANDBY
5V : 5V@0.5A ; tolerance 5%, ripple : 100mVp-p(max.)
SB
±
PACKING
3.9Kg; 4pcs/16Kg/0.9CUFT
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
7. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
μ