5–21
CII Mid-Range Relays
CII Mid-Range Relays
5
FCA-125 Series, 25 Amperes, SPDT
The Series FCA-125 relay
is a polarized single-side
stable design, where the
f
lux from a permanent
magnet provides the
armature holding force in
the deactivated state, and
its flux path is switched and
combined with the coil flux
in the operated state.
This results in appreciably
increased contact pressure
in both states over that of a
s
pring return nonpolar
design. We also
manufacture other versions
of this relay:
FCA-325 — 25 Ampere
3
PDT Relay
FCAC-325 — 25 Ampere
3PST-NO Relay with 2 amp
SPDT auxiliary
Product Facts
n Hermetically Sealed
n All Welded Construction
n Balanced Force
n Permanent Magnet Drive
n Contacts — Silver Cadmium
Oxide with Gold Plating
n Coils for DC, 50 to 400Hz
and 400Hz AC
n Weight 1.6 ounces max.
(45.4 grams)
n Qualified to M6106/19,
M83536/36, /37
Contact Rating — Amperes
Ratings Are Continuous Duty
Type of Life (Min.)
28 VDC
115VAC 115VAC
Load Cycles x 10
3
400Hz 60Hz*
Resistive 50 25 25 10
Inductive 10 12 — 10
Inductive 20 — 15 —
Motor 50 10 10 8
Lamp 50 55—
*60 Hz loads rated for 10,000 operations
Overload Current — 50 AMPS DC, 80 AMPS 400Hz
Rupture Current — 60 AMPS DC, 100 AMPS 400Hz
Contact Make Bounce —1 MILLISECOND AT NOMINAL VOLTAGE
Max. Contact Drop at 25 Amps — INITIAL 0.150 VOLTS
End of Life — 0.175 VOLTS
Coil Data
Over Temperature Range
Coil Nominal Freq. DC Res.
Pickup or Dropout or Must Hold
Code Voltages Hz AC Amps (B)
Below Volts Above Volts Voltage (C)
16 DC 20 Ω 4.5 0.3 2.5
2 12 DC 80 Ω 9.0 0.75 4.5
3 28 DC 320 Ω 18.0 1.5 7.0
4 (A) 28 DC 320 Ω 18.0 1.5 7.0
5 48 DC 920 Ω 32.0 2.5 14.0
6 28 400Hz 180 mA 22.0 1.25 10.0
7 28 50/400Hz 100 mA 22.0 1.25 10.0
8 115 400 Hz 40 mA 90.0 5.0 40.0
9 115 50/400 Hz 30 mA 95.0 5.0 40.0
A. CODE 4 COILS HAVE BACK EMF SUPPRESSION TO 42 VOLTS MAX.
B. DC COIL RESISTANCE ± 10% AT 25˚C; AC COIL MAX. CURRENT AT NOMINAL VOLTAGE.
C. RELAY WILL STAY IN PICKED-UP STATE DOWN TO MUST HOLD VOLTAGES SHOWN.
D. MAX. OVERVOLTAGE: 6 & 12 VDC COILS 120% OF NOMINAL; ALL OTHERS 110% OF NOMINAL.
E. COILS AVAILABLE FOR OTHER VOLTAGES AND FOR AC 50/60HZ.
NOTE: Only DC Coil Models are QPL Approved.
General Specifications
Temperature Rating —
-70˚C TO + 125˚C
Altitude — 300,000 Feet
Shock* —
Z, Y, & X Enclosures —
200 g for 6 mS
W & M Enclosures (Stud Mtg.) —
100 g for 6 mS
Vibration, Sinusoidal* —
Z, Y, & X Enclosures —
30 g 33-3000Hz
W & M Enclosures (Stud Mtg.) —
20 g 33-3000Hz
Vibration, Random* —
Z, Y, & X Enclosures —
0.4 g
2
/Hz 50-2000Hz
W & M Enclosures (Stud Mtg.) —
0.2 g
2
/Hz 50-2000Hz
Dielectric Strength —
At Sea Level —
All circuits to ground and circuit to
circuit — 1250 V rms
Coil to ground — 1000 V rms
At 80,000 Feet — 350 V rms
Insulation Resistance —
Initial (500 VDC) — 100 MΩ Min.
After Life or Environmental Tests —
50 MΩ Min.
Operate Time at Nominal
Voltage —
DC Relays — 10 ms or less
AC Relays — 15 ms or less
Release Time at Nominal
Voltage —
DC Relays — 10 ms or less
AC Relays — 50 ms or less
* Max. contact opening under vibration
or shock 10 microseconds
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.