7
Figure 19. OP1dB vs Frequency and Temperature for Optimum OIP3 and Fmin
at 5V 50mA
0
2
4
6
8
10
12
14
16
18
20
22
24
1.5 1.9 2 2.2 2.5
Frequency (GHz)
OP1dB(dBm)
25°C
85°C
-40°C
Below is the table showing the MGA-634P8 Re ection Coe cient Parameters tuned for maximum OIP3, Vdd = 5V, Idd
= 50mA
Frequency (GHz)
Gamma Load position
OIP3 (dBm) OP1dB (dBm)Magnitude Angle
1.5 0.42 20 41.13 21.26
1.9 0.28 30 41.8 21.19
2 0.28 30 41.56 20.89
2.2 0.42 40.1 41.95 21.36
2.5 0.57 57.6 42.24 19.65
[2]
[1]
[3]
[4]
[7]
[8]
[6]
[5]
bias
RFinput
Reference Plane
RFoutput
Reference Plane
Figure 20
Notes:
1. The maximum OIP3 values are calculated based on Load pull
measurements on approximately 136 di erent impedances using
Focus’ Load Pull test system.
2. Measurements are conducted on 0.010 inch think ROGER 4350. The
input reference plane is at the end of the RFin pin and the output
reference plane is at the end of the RFout pin as shown in Figure 20.
3. Gamma Load for maximum OIP3 with biasing of 5V 40mA, 5V 50mA,
5V 70mA and 5V 80mA from 1.5GHz to 2.5GHz are available upon
request.