1584046

https://www.phoenixcontact.com/pi/products/1584046
08/18/2018Page1/4
Contact insert-HC-DD24-I-CT-F-1584046
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
HEAVYCON female insert, DD24 series, 24-pos., crimp connection
Why buy this product
Can be used in rail vehicles, satisfy DIN EN 45545-2 with requirement sets R22, R23, and R24 in hazard levels HL1, HL2, and HL3.
Key Commercial Data
Packing unit 1 STK
GTIN
GTIN 4046356133357
Technical data
General
Note
For HEAVYCON ADVANCE and HEAVYCON housing of B6 type, crimp
contacts CK 1,6-ED (crimp contacts not included in the scope of supply).
Plug-in connections may only be operated only when there is no load/
voltage.
Connection method Crimp connection
Degree of pollution 3
Overvoltage category III
Number of positions 24+PE
Insertion/withdrawal cycles ≥ 500
Size B6
Contact numbering 1 - 24
Conductor cross section 0.14 mm² ... 2.5 mm²
Connection cross section AWG 26 ... 14
Stripping length of the individual wire 8 mm (0.14...1.5mm²)
6 mm (2.5 mm²)
Assembly instructions
-Housing heights with h >= 72 mm are recommended in the case of a
large number of wires.
https://www.phoenixcontact.com/pi/products/1584046
08/18/2018Page2/4
Contact insert-HC-DD24-I-CT-F-1584046
Technical data
General
-Use of HC-CST (1676857) coding pins and HC-CBU (1676860) coding
sockets has been prescribed.
Connection Connectors may be plugged in only when there is no load/voltage.
Ambient conditions
Ambient temperature (operation) -40 °C ... 125 °C (including heating up of contacts)
Material data
Contact material Copper alloy
Contact surface material Ag (alternatively Au)
Contact carrier material PC
Standards/regulations
PC: Fire protection in rail vehicles - requirement sets R22, R23, and R24
acc. to DIN EN 45545-2 (Risk level HL1 - HL3)
Electrical characteristics
Rated voltage (III/3) 250 V
Rated surge voltage 4 kV
Rated current 10 A
Standards and Regulations
Connection in acc. with standard CSA
Constructional and testing regulations DIN VDE 0627/86
DIN VDE 0110/02.79
DIN VDE 0110-1/04.97
IEC 60664-1, DIN IEC 60512
IEC 60352
Flammability rating according to UL 94 V0
Environmental Product Compliance
China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Drawings
Dimensional drawing
34
27
34,5
50,5
44
Female insert
Diagram
Ambienttemperature[°C]
Operating current[A]
0
4
2
20
18
16
14
12
10
8
6
20
20
0
0
40
40
60
60
80
80
100
100
120
120
1
2
=1,5mm
=2,5mm
2
2
1
2
DD24
DD42
DD108
DD72
DD24
DD42
DD108
DD72
Derating diagram
https://www.phoenixcontact.com/pi/products/1584046
08/18/2018Page3/4
Contact insert-HC-DD24-I-CT-F-1584046
Dimensional drawing
27
20
35
36
46
44
Ø3,4
Mounting cutout when used without housing
Dimensional drawing
34
27
34,5
A
B
Schematic diagram
1
21
4
24
Connector pin assignment, connection side
Approvals
Approvals
Approvals
CSA / UL Recognized / cUL Recognized / GL / EAC / cULus Recognized
Ex Approvals
Approval details
CSA
http://www.csagroup.org/services-industries/product-listing/ 013631_6233_01
Nominal voltage UN 250 V
Nominal current IN 7 A
mm²/AWG/kcmil 26-14
UL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm FILE E 118976
Nominal voltage UN 250 V

1584046

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Heavy Duty Power Connectors Female DD24 24P Crimp
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union