1. Kit Contents
The C8051F00x/01x Development Kit contains the following items:
C8051F005 Target Board
C8051Fxxx Development Kit Quick-Start Guide
Silicon Laboratories IDE and Product Information CD-ROM. CD content includes:
Silicon Laboratories Integrated Development Environment (IDE)
Keil Software 8051 Development Tools (macro assembler, linker, evaluation ‘C’ compiler)
Source code examples and register definition files
Documentation
C8051F00x/01x Development Kit User’s Guide (this document)
AC to DC Power Adapter
USB Debug Adapter (USB to Debug Interface)
USB Cable
2. Hardware Setup using a USB Debug Adapter
The target board is connected to a PC running the Silicon Laboratories IDE via the USB Debug Adapter as shown
in Figure 1.
1. Connect the USB Debug Adapter to the JTAG connector on the target board with the 10-pin ribbon cable.
2. Connect one end of the USB cable to the USB connector on the USB Debug Adapter.
3. Connect the other end of the USB cable to a USB Port on the PC.
4. Connect the ac/dc power adapter to power jack P1 on the target board.
Notes:
•Use the Reset button in the IDE to reset the target when connected using a USB Debug Adapter.
Remove power from the target board and the USB Debug Adapter before connecting or disconnecting the
ribbon cable from the target board. Connecting or disconnecting the cable when the devices have power can
damage the device and/or the USB Debug Adapter.
Figure 1. Hardware Setup using a USB Debug Adapter
PC
USB
Cable
USB Debug Adapter
AC/DC
Adapter
Target Board
SILICON LABORATORIES
PWR
P1.6
P3.7RESET
Port 4Port 3Port 1
Port 2 Port 0
MCU
Silicon Laboratories
USB DEBUG ADAPTER
Run
StopPower
C8051F00x/01x-DK
2 Rev. 0.6
3. Software Setup
The included CD-ROM contains the Silicon Laboratories Integrated Development Environment (IDE), Keil software
8051 tools and additional documentation. Insert the CD-ROM into your PC’s CD-ROM drive. An installer will auto-
matically launch, allowing you to install the IDE software or read documentation by clicking buttons on the Installa-
tion Panel. If the installer does not automatically start when you insert the CD-ROM, run autorun.exe found in the
root directory of the CD-ROM. Refer to the readme.txt file on the CD-ROM for the latest information regarding
known IDE problems and restrictions.
4. Silicon Laboratories Integrated Development Environment
The Silicon Laboratories IDE integrates a source-code editor, source-level debugger and in-system Flash program-
mer. The use of third-party compilers and assemblers is also supported. This development kit includes the Keil
Software A51 macro assembler, BL51 linker and evaluation version C51 ‘C’ compiler. These tools can be used
from within the Silicon Laboratories IDE.
4.1. System Requirements
The Silicon Laboratories IDE requirements:
Pentium-class host PC running Microsoft Windows 98SE or later.
One available COM or USB port.
64 MB RAM and 40 MB free HD space recommended.
4.2. Assembler and Linker
A full-version Keil A51 macro assembler and BL51 banking linker are included with the development kit and are
installed during IDE installation. The complete assembler and linker reference manual can be found under the Help
menu in the IDE or in the “SiLabs\MCU\hlp” directory (A51.pdf).
4.3. Evaluation C51 ‘C’ Compiler
An evaluation version of the Keil C51 ‘C’ compiler is included with the development kit and is installed during IDE
installation. The evaluation version of the C51 compiler is the same as the full professional version except code
size is limited to 4 kB and the floating point library is not included. The C51 compiler reference manual can be
found under the Help menu in the IDE or in the “SiLabs\MCU\hlp” directory (C51.pdf).
4.4. Using the Keil Software 8051 Tools with the Silicon Laboratories IDE
To perform source-level debugging with the IDE, you must configure the Keil 8051 tools to generate an absolute
object file in the OMF-51 format with object extensions and debug records enabled. You may build the OMF-51
absolute object file by calling the Keil 8051 tools at the command line (e.g. batch file or make file) or by using the
project manager built into the IDE. The default configuration when using the Silicon Laboratories IDE project
manager enables object extension and debug record generation.
Refer to Applications Note
AN104 -
Integrating
Keil 8051 Tools Into the Silicon Labs IDE
in the “SiLabs\MCU\Documentation\Appnotes” directory on the CD-
ROM for additional information on using the Keil 8051 tools with the Silicon Laboratories IDE.
To build an absolute object file using the Silicon Laboratories IDE project manager, you must first create a project. A
project consists of a set of files, IDE configuration, debug views, and a target build configuration (list of files and tool
configurations used as input to the assembler, compiler, and linker when building an output object file).
The following sections illustrate the steps necessary to manually create a project with one or more source files, build
a program and download the program to the target in preparation for debugging. (The IDE will automatically create a
single-file project using the currently open and active source file if you select
Build/Make Project
before a project is
defined.)
C8051F00x/01x-DK
Rev. 0.6 3
4.4.1. Creating a New Project
1. Select Project
New Project to open a new project and reset all configuration settings to default.
2. Select File
New File to open an editor window. Create your source file(s) and save the file(s) with a rec-
ognized extension, such as .c, .h, or .asm, to enable color syntax highlighting.
3. Right-click on “New Project” in the Project Window. Select Add files to project. Select files in the file
browser and click Open. Continue adding files until all project files have been added.
4. For each of the files in the
Project
Window
that you want assembled, compiled and linked into the target
build, right-click on the file name and select
Add file to build
. Each file will be assembled or compiled as
appropriate (based on file extension) and linked into the build of the absolute object file.
Note:
If a project contains a large number of files, the “Group” feature of the IDE can be used to organize.
Right-click on “New Project” in the
Project Window
. Select
Add Groups to project
. Add pre-defined
groups or add customized groups. Right-click on the group name and choose
Add file to group
. Select files
to be added. Continue adding files until all project files have been added.
4.4.2. Building and Downloading the Program for Debugging
1. Once all source files have been added to the target build, build the project by clicking on the Build/Make
Project button in the toolbar or selecting Project
Build/Make Project from the menu.
Note: After the project has been built the first time, the Build/Make Project command will only build the
files that have been changed since the previous build. To rebuild all files and project dependencies, click
on the Rebuild All button in the toolbar or select Project
Rebuild All from the menu.
2.
Before connecting to the target device, several connection options may need to be set.
Open the
Connection Options
window by selecting
Options
Connection Options...
in the IDE menu. First, select
the appropriate adapter in the “Serial Adapter” section. Next, the correct “Debug Interface” must be selected.
C8051F00x/01x
family devices use the JTAG debug interface. Once all the selections are made, click the OK
button to close the window.
3. Click the
Connect
button in the toolbar or select
Debug
Connect
from the menu to connect to the device.
4. Download the project to the target by clicking the Download Code button in the toolbar.
Note: To enable automatic downloading if the program build is successful select Enable automatic con-
nect/download after build in the Project
Target Build Configuration dialog. If errors occur during the
build process, the IDE will not attempt the download.
5. Save the project when finished with the debug session to preserve the current target build configuration,
editor settings and the location of all open debug views. To save the project, select Project->Save Project
As... from the menu. Create a new name for the project and click on Save.

C8051F005DK-T

Mfr. #:
Manufacturer:
Silicon Labs
Description:
C8051F0XX EVAL BRD
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union