MS5803-30BA
Miniature 30 bar Module
SENSOR SOLUTIONS ///MS5803-30BA
09/2015
Page 4
PERFORMANCE SPECIFICATIONS (CONTINUED)
PRESSURE OUTPUT CHARACTERISTICS (V
DD
= 3 V, T = 25°C UNLESS OTHERWISE NOTED)
Parameter
Conditions
Min.
Typ.
Max
Unit
Operating Pressure Range
P
range
Full Accuracy
0
30
bar
Absolute Accuracy,
Temperature range 0 … 40 °C
0 … 6 bar
0 … 20 bar
0 … 30 bar
-50
-100
-250
+50
+100
+250
mbar
Absolute Accuracy,
Temperature range -40 … 85 °C
0 … 6 bar
0 … 20 bar
0 … 30 bar
-100
-200
-400
+100
+200
+400
mbar
Maximum error with supply
voltage (1)
V
DD
= 1.8 V … 3.6 V
+/-50
mbar
Long-term stability
-50
mbar/yr
Resolution RMS
OSR 4096
2048
1024
512
256
0.5
0.75
1
1.5
2.5
mbar
(1) With autozero at 3V point
TEMPERATURE OUTPUT CHARACTERISTICS (V
DD
= 3 V, T = 25°C UNLESS OTHERWISE NOTED)
Parameter
Conditions
Min.
Typ.
Max
Unit
Absolute Accuracy
0 …10 bar
-20..85°C
-40..85°C
-0.8
-2.0
-4.0
+0.8
+2.0
+4.0
°C
Maximum error with supply
voltage(1)
V
DD
= 1.8 V … 3.6 V
+/-0.5
°C
Resolution RMS
OSR 4096
2048
1024
512
256
0.002
0.003
0.005
0.008
0.012
°C
(1) With autozero at 3V point
+
MS5803-30BA
Miniature 30 bar Module
SENSOR SOLUTIONS ///MS5803-30BA
09/2015
Page 5
PERFORMANCE SPECIFICATIONS (CONTINUED)
DIGITAL INPUTS (PS, CSB, DIN, SCLK, SDA, SCL)
Parameter
Symbol
Conditions
Min.
Typ.
Max
Unit
Serial data clock
SCLK
SPI protocol
20
MHz
Serial data clock
SCL
I2C protocol
400
kHz
Input high voltage
V
IH
Pins CSB
80% V
DD
100% V
DD
V
Input low voltage
V
IL
0% V
DD
20% V
DD
V
Input leakage current
I
leak25°C
at 25°c
0.15
µA
CS low to first SCLK rising
tCSL
21
ns
CS low from last SCLK falling
tCSH
21
ns
DIGITAL OUTPUTS (DOUT, SDA, SCL)
Parameter
Symbol
Conditions
Min.
Typ.
Max
Unit
Output high voltage
V
OH
I
source
= 0.6 mA
80% V
DD
100% V
DD
V
Output low voltage
V
OL
I
sink
= 0.6 mA
0% V
DD
20% V
DD
V
Load capacitance
C
LOAD
16
pF
MS5803-30BA
Miniature 30 bar Module
SENSOR SOLUTIONS ///MS5803-30BA
09/2015
Page 6
PERFORMANCE CHARACTERISTICS
PRESSURE ERROR VS PRESSURE AND TEMPERATURE
TEMPERATURE ERROR VS TEMPERATURE
PRESSURE AND TEMPERATURE ERROR VS POWER SUPPLY
-500.00
-400.00
-300.00
-200.00
-100.00
0.00
100.00
200.00
300.00
400.00
500.00
0 5000 10000 15000 20000 25000 30000
Pressure error [mbar]
Pressure [mbar]
Absolute pressure accuracy with 2nd order compensation
Typical
85
25
-40
-400.0
-300.0
-200.0
-100.0
0.0
100.0
200.0
300.0
400.0
-40 -20 0 20 40 60 80
Pressure error [mbar]
Temperature C]
Pressure accuracy vs temperature
Typical
30000mbar
2nd order
14000 mbar
2nd order
30000 mbar
1st order
14000mbar
1st order
-2.0
0.0
2.0
4.0
6.0
8.0
10.0
-40 -20 0 20 40 60 80
Temperature error [°C]
Temperature C]
Temperature accuracy vs temperature
Typical
30000mbar
2nd order
1000 mbar
2nd order
30000mbar
1st order
1000 mbar
1st order
-50.0
-30.0
-10.0
10.0
30.0
50.0
1.8 2 2.2 2.4 2.6 2.8 3 3.2 3.4 3.6
Pressure error [mbar]
Supply Voltage [V]
Pressure error vs supply voltage at 25°C
Typical
1000 mbar
4000 mbar
6000 mbar
14000 mabr
-0.5
-0.3
-0.1
0.1
0.3
0.5
1.8 2 2.2 2.4 2.6 2.8 3 3.2 3.4 3.6
Temperature error [°C]
Supply Voltage [V]
Temperature error vs supply voltage at 25°C
Typical
1000 mbar
4000 mbar
6000 mbar
14000 mbar

MS580330BA01-00

Mfr. #:
Manufacturer:
TE Connectivity / Measurement Specialties
Description:
Board Mount Pressure Sensors MS5803-30BA 30BAR WHITE GEL
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union