Electrical characteristics ST2042
8/13 Doc ID 9679 Rev 6
Note: 1 Pulse testing techniques maintain junction temperature close to ambient temperature:
thermal effect must be takes into account separately.
2 Specified by design, not production tested.
3 Guaranteed by design.
Table 8. Supply current characteristics
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
SOL
Current low level
output
V
IENX
= V
I
, no load, 0.025 1
μA
V
IENX
= V
I
, no load, T
J
= -40 to 125 °C 10
I
SOH
Current low high
output
V
IENX
= 0, no load, 70 90
μA
V
IENX
= 0, no load, T
J
= -40 to 125 °C 100
I
L
Output leakage
current
V
IENX
= V
I
, output connected to GND,
T
J
= -40 to 125 °C
10 μA
Table 9. Undervoltage characteristics
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
IL
Low level input
voltage
22.5V
V
HYS
Hysteresis 100 mV
Table 10. Overcurrent (OC) characteristics
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
SINK
Sink current V
O
= 5 V 10 mA
V
O
Output low
voltage
I
O
= 5 mA 0.5 V
I
OFF
OFF-state
current
V
O
= 5 V, V
O
= 3.3 V 1 μA
T
FB
Fault-blanking
period
V
I
= 5.5 V, T
J
= 25 °C
(See Note 2 and Note 3)
210 ms