GE18I48-P1J

TYPE
ORDER NO.
Australian type U.K type European type US type
Mix four type
AC plug-AU AC plug-UK AC plug-EU AC plug-US
AC plug-MIX
GE18 05-P1J GE18 07-P1J GE18 09-P1J GE18 12-P1J GE18 15-P1J GE18 18-P1J GE18 24-P1J GE18 48-P1J
IIIIIIII
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
POWER SUPPLY MAIN BODY ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
Note.2
RATED CURRENT
OUTPUT
SETUP, RISE, HOLD UP TIME
VOLTAGE RANGE
Note.7
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
INRUSH CURRENT (max.)
LEAKAGE CURRENT (max.)
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
LIFE
DIMENSION
OTHERS
DC OUTPUT
NOTE
PLUG
CABLE
OVERLOAD
OVER VOLTAGE
9V7.5V5V
12V 15V 18V 24V 48V
2.0A1.73A2.4A
1.5A 1.2A 1.0A 0.75A 0.375A
CURRENT RANGE 0 ~ 2.0A0 ~ 1.73A0 ~ 2.4A
0 ~ 1.5A 0 ~ 1.2A 0 ~ 1.0A 0 ~ 0.75A 0 ~ 0.375A
RIPPLE & NOISE (max.)
Note.3
100mVp-p75mVp-p50mVp-p
120mVp-p 150mVp-p 180mVp-p 240mVp-p 300mVp-p
VOLTAGE TOLERANCE
Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
±3.0% ±3.0% ±3.0%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±5.0%
±5.0%
±5.0%
±5.0%
±1.0% ±1.0% ±1.0%
±5.0%
±5.0%
±3.0%
±3.0%
±3.0%
±3.0% ±3.0% ±3.0% ±3.0%
4000ms, 100ms, 30ms / 230VAC 4000ms, 100ms, 10ms / 115VAC at full load
90 ~ 264VAC 135 ~ 370VDC
47 ~ 63Hz
0.7A / 100VAC 0.4A / 230VAC
COLD START 40A / 100VAC 80A / 230VAC
0.25mA / 240VAC
110% ~ 200% rated output power
115% ~ 135% rated output voltage
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
100Khrs min. MIL-HDBK-217F (25 )
2 years : 100% load 30 , 8 hours / day
-10 ~ +50 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
±℃0.03% / (0 ~ 30 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
81*43*40.5mm (L*W*H)
CONNECTOR
RATED POWER (max.)
18W 18W18W13W12W
18W 18W 18W
See page 2 ; Other type available by customer requested
See page 2 ; Other type available by customer requested
Features :
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Clamp by zener diode
ENVIRONMENT
PROTECTION
File Name:GE18-SPEC 2015-09-15
18WAC-DC Interchangeable Industrial Adaptor
GE18 series
Interchangeable AC plugs (plug kit sold separately)
Universal AC input / Full range
No load power consumption< 0.075W
Energy efficiency Level
Comply with EISA 2007/DoE and EU ErP
Class power (without earth pin)II
Protections: Short circuit / Overload / Over voltage
Pass LPS
Fully enclosed plastic case
LED indicator for power on
2 years warranty
UL60950-1, CSA C22.2, TUV EN60950 -1, AS/NZS 60950.1, CCC GB4943 approved
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022, EN61000-3-2,3, FCC part15, GB9254 class B, GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
PACKING
134g ; 50pcs / 8.4kg / CARTON
85%82.5%80.5%
86% 86.5%
87% 87% 87%
SPECIFICATION
Interchangeable AC plug specifically for GE series
EMC IMMUNITY
EMC EMISSION
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load
7.Derating may be needed under low input voltage. Please check the derating curve for more details.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
9.Main body unit and AC inlet plug should be ordered separately ; it needs to be used along with any of the AC inlet plug.
SAFETY &
EMC
(Note. 8)
IIIIIIII
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
GE18 05 GE18 07 GE18 09 GE18 12 GE18 15 GE18 18 GE18 24 GE18 48
Mechanical Specification
File Name:GE18-SPEC 2015-09-15
Static Characteristics
11 0.5mm±
43
81
Plug Assignment
Standard plug: P1J
P/N
CENTER
OUTPUT
+
P1J
40.5
36.5
INPUT VOLTAGE (VAC) 60Hz
AMBIENT TEMPERATURE ( )
90 100 120115 160140 200180 240220 264
LOAD (%)
90
100
80
70
60
50
40
95
LOAD (%)
-10 10 20 30 40
75
50
100
50
Derating Curve
Unit:mm
C"+"
18WAC-DC Interchangeable Industrial Adaptor
GE18 series
ID 2.1 x OD 5.5
InsideOutside
AWM2468 16AWG 1000 for 5~12V
±
50mm
AWM2468 18AWG 1500 for 15~48V
±
100mm

GE18I48-P1J

Mfr. #:
Manufacturer:
MEAN WELL
Description:
Wall Mount AC Adapters 18W 48V 0.375A