https://www.phoenixcontact.com/pi/products/2986232
08/19/2018Page4/6
Safety module-PSR-SPP- 24DC/TS/S-2986232
Technical data
Connection data
Conductor cross section flexible max. 1.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 16
Stripping length 8 mm
Safety-related characteristic data
Stop category 0
Designation IEC 61508 - High demand
Safety Integrity Level (SIL) 2 ()
3 (2-channel parameterization)
Designation IEC 61508 - Low demand
Safety Integrity Level (SIL) 2 ()
3 (2-channel parameterization)
Designation EN ISO 13849
Performance level (PL) d ()
e (2-channel parameterization)
Category 2 ()
4 (2-channel parameterization)
Designation EN 62061
Safety Integrity Level Claim Limit (SIL CL) 2 ()
3 (2-channel parameterization)
Designation EN50156
Safety Integrity Level (SIL) max. 3 (Reference IEC61508)
Standards and Regulations
Designation Air clearances and creepage distances between the power circuits
Standards/regulations DIN EN 50178
Degree of pollution 2
Overvoltage category III
Vibration (operation) 2g
Shock (operation) 10g (Δt=11ms, threeshocksineach space direction)
10g (Δt=16ms, continuous shock, 1000 shocks in each space
direction)
Environmental Product Compliance
China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values