(2/11)
20160622 / sensor_humidity_chs_en.fm
SENSORS
Please be sure to request delivery specifications that provide further details on the features and specifications of the products for proper and safe use.
Please note that the contents may change without any prior notice due to reasons such as upgrading.
Humidity Sensor
APPLICATION
Refrigerators (condensation prevention),
Air conditioners (indoor humidity control),
PPCs, LBPs (image quality control),
Industrial electronic humidity sensors, air conditioners for plant factories, etc.
PRODUCT LINEUP
ASSEMBLY
ELEMENT
Overview of the CHS series
Type Driving range
Guaranteed
measurement
accuracy range
Accuracy Driving voltage Output voltage Shapes Size
CHS-UPS
5 to 95%RH
0 to +50°C
5 to 95%RH
+25°C
±3%RH
5VDC
0 to 1.0V
SQUARE TYPE 27×11.5×6.5
CHS-UPR ROUND TYPE ø20×9
CHS-UGS
±5%RH
SQUARE TYPE 27×11.5×6.5
CHS-UGR ROUND TYPE ø20×9
CHS-MSS
20 to 85%RH
+25°C
SQUARE TYPE 20×10×5
CHS-CGC5-28
50%RH
+25°C
±7%RH 0 to 2.0V PCB ASSY 19×21×12.6
Type Driving range
Guaranteed
measurement
accuracy range
Accuracy Driving voltage Output impedance Shapes Size
CHS-ESS-CA5
5 to 95%RH
0 to +50°C
50%RH
+25°C
±5%RH AC5V max.
1k to 80M :
(AC1V/1kHz)
SQUARE TYPE 9.0×6.5×3.7
Product compatible with RoHS directive
RoHS Directive Compliant Product: See the following for more details.https://product.tdk.com/info/en/environment/rohs/index.html