HSP-200-4.2

Universal AC input / Full range
Built-in active PFC function
Low leakage current<1.0mA
Protections: Short circuit / Overload / Over voltage / Over temperature
Low profile:31mm
Conformal coated
LED indicator for power on
3 years warranty
3.6~4.4V
VOLTAGE ADJ. RANGE
4.5~5.5V
110~140% rated output power
SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVER TEMPERATURE
SAFETY STANDARDS
EMC EMISSION
EMC IMMUNITY
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
2000ms, 200ms/230VAC 3000ms, 200ms/115VAC at full load
90 ~ 264VAC 127 ~ 370VDC
Cold start 70A/230VAC
<1.0mA / 240VAC
4.6 ~ 5.4V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Compliance to EN55032 (CISPR32),GB9254,Class B, EN61000-3-2,-3,GB17625.1, EAC TP TC 020
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
±℃ )0.03%/ (0 ~ 60
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
204K hrs min. MIL-HDBK-217F (25 )
PF 0.95/230VAC PF 0.98/115VAC at full load≥≥
16ms/230VAC 16ms/115VAC at full load
88%
±1.0%
±0.5%
±2.0%
150mVp-p
4.2V
40A
HSP-200-4.2
File Name:HSP-200-SPEC 2018-01-09
Features :
HSP-200 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.450 450 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
ENVIRONMENT
SAFETY &
EMC
(Note 5)
PROTECTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.0KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25 / 70%RH
5.6 ~ 7.0V
88.5%
±1.0%
±0.5%
±2.0%
150mVp-p
5V
40A
HSP-200-5
200W Single Output with PFC Function
Compliance to EN61000-4-2,3,4,5,6,8,11;EN55024, light industry level (surge 4KV), criteria A, EAC TP TC 020
SHORT CIRCUIT
Protection type : Hiccup mode, recovers automatically after fault condition is removed
210*62*31mm (L*W*H)
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Shut down O/P voltage, recovers automatically after fault condition is removed
3.0A/115VAC 2.0A/230VAC
0 ~ 40A
CURRENT RANGE
0 ~ 40A
168W
RATED POWER
(convection)
200W
0.52kg; 20pcs/ 11.4kg/0.76CUFT
2.5A/115VAC 1.5A/230VAC
47 ~ 63Hz
UL60950-1,TUV EN60950-1,CCC GB4943,EAC TP TC 004 approved
Bauar
Sicherheit
egel gema
t gepruft
od
be
www.
ID 2000000000
tuv.com
wac g
os
S
&
E
PWM
CIRCUIT
DETECTION
O.L.P.
EMI
FILTER
APFC
POWER
SWITCH-
FILTER
&
SYNCHRONOUS
I/P
FG
ING
CONVERTER
O.V.P.
BRIDGE
RECTIFIERS
Block Diagram
Mechanical Specification
CASE NO.: 232B Unit:mm
O.T.P.
HSP-200 series
200W Single Output with PFC Function
File Name:HSP-200-SPEC 2018-01-09
CONTROLLER
RECTIFIERS
Derating Curve Static Characteristics
+V
-V
AMBIENT TEMPERATURE ( )
load(%)
(HORIZONTAL)
INPUT VOLTAGE (V) 60Hz
90 100 110 135 155 230 264
fosc=90Khz
load(%)
40
80
100
60
14
20
70
1
2
3
4
4 3.3
Pin No.
1
3
2
Assignment
AC/L
AC/N
AC Input Terminal(TB1) pin NO. Assignment
Terminal
DG28C-B-03P
3
2
1
DC Output Terminal pin NO. Assignment
Pin No.
1,2
3,4
Assignment
-V
+V
Terminal
K14-20A(H)
13
SVR1
TB1
210
62
46.4
7.8
2 206
31
-30 -25 -10 0 15 30 50 60 70
20
40
60
80
100
4.2V
5V
File Name:HSP-200-SPEC 2018-01-09
1.Operate with additional aluminum plate
on the bottom.The size of the suggested aluminum plate is shown as below. And for optimizing thermal performance, the aluminum plate must have an even and
smooth surface (or coated with thermal grease), and HSP-200 series must be firmly mounted at the center of the aluminum plate.
In order to meet the“Derating Curve”and the “Static Characteristics” ,HSP-200 series must be installed onto an aluminum plate(or the cabinet of the same size)
Installation
2.For heat dissipation, at least 5cm installation distance around the PSU should be kept, shown as below:
13
SVR1
5cm
5
cm
5
cm
5cm
5
cm
M3*4
3
450
450
HSP-200 series
200W Single Output with PFC Function

HSP-200-4.2

Mfr. #:
Manufacturer:
Description:
Switching Power Supplies 168W 4.2V 40A Sign Panel PS
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet