E2K-F7MC1-10

CSM_E2K-F_DS_E_5_3
1
Flat Proximity Sensor
E2K-F
Flat Capacitive Sensor with a
Thickness of Only 10 mm
• Flat Sensor with excellent space efficiency.
(Model with built-in Amplifier is only 10 mm thick.)
• Direct mounting onto a metallic surface is possible.
Ordering Information
Sensors [Refer to Dimensions on page 4.]
* Adjustable range
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Be sure to read Safety Precautions on
page 3.
Appearance Sensing distance Output configuration
Model/Operation mode
NO NC
DC 3-wire
NPN
E2K-F10MC1 2M E2K-F10MC2 2M
E2K-F10MC1-A 2M E2K-F10MC2-A 2M
Flat
Unshielded
10 mm
10 mm
[4 to 10 mm *]
E2K-F
2
Ratings and Specifications
* The value for the E2K-F10MC@-A is when it is adjusted to 10 mm.
Engineering Data (Reference Value)
Item Model E2K-F10MC@-A E2K-F10MC@
Sensing distance
10 mm (Sensing distance adjustable range: 4 to 10 mm)
10 mm ±10%
Set distance 0 to 7.5 mm *
Differential travel 15% max. of sensing distance
Detectable object Conductors and dielectrics
Standard sensing object Grounded metal plate: 50 × 50 × 1 mm
Response frequency 100 Hz
Power supply voltage (operating
voltage range)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Current consumption 10 mA max. at 24 VDC
Control
output
Load current NPN open collector, 100 mA max. (at 30 VDC)
Residual voltage 1.5 V max. (Load current: 100 mA, Cable length: 2 m)
Indicators Detection indicator (red)
Number of turns of sensitivity
adjustment
12 turns
Operation mode (with sensing
object approaching)
NO (Refer to the timing charts under I/O Circuit Diagrams on page 3 for details.)
Protection circuits Reverse polarity protection, Surge suppressor
Ambient temperature range Operating/Storage: 10 to 55°C (with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95% Operating/Storage: 35% to 95%
Temperature influence ±15% max. of sensing distance at 23°C in the temperature range of 10 to 55°C
Voltage influence ±2.5% max. of sensing distance at rated voltage at rated voltage ±10%
Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s
2
3 times each in X, Y, and Z directions
Degree of protection IP64 (IEC) IP66 (IEC)
Connection method Pre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 35 g
Materials
Case
Heat-resistant ABS
Sensing surface
Accessories Instruction manual
Sensing Area (Grounded Metal Plate) Influence of Sensing Object Size and
Material
121620
1
2
3
4
5
6
7
8
9
10
11
12
X
Y
20161284048
Left and
right
Distance X (mm)
Sensing Head
Distance Y (mm)
121620
1
2
3
4
5
6
7
8
9
10
11
12
20161284048
X
Y
Distance X (mm)
Sensing Head
Distance Y
(mm)
Up and
down
100
1
2
3
4
5
6
7
8
9
10
80706050403020
Grounded metal plate (t = 1)
Non-grounded
metal plate (t = 10)
Glass (t = 10)
Phenol (t = 10)
Side length of sensing object (mm
)
Distance (mm)
3
E2K-F
I/O Circuit Diagrams
Safety Precautions
Refer to Warranty and Limitations of Liability.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Do not use this product under ambient conditions that exceed the
ratings.
Design
Sensing Object Material
The E2K-F can detect almost any type of object. The sensing distance
of the E2K-F, however, will vary with the electrical characteristics of
the object, such as the conductance and inductance of the object, and
the water content and capacity of the object. The maximum sensing
distance of the E2K-F will be obtained if the object is made of
grounded metal. There are objects that cannot be detected indirectly.
Therefore, be sure to test the E2K-F in a trial operation with the
objects before using the E2K-F in actual applications.
Influence of Surrounding Metal
Separate the E2K-F from surrounding metal as shown below.
Mutual Interference
When mounting more than one E2K-F face-to-face or side-by-side,
separate them as shown below.
Effects of a High-frequency Electromagnetic Field
The E2K-F may malfunction if there is an ultrasonic washer, high-
frequency generator, transceiver, portable telephone, or inverter
nearby.
For major measures, refer to Noise of Warranty and Limitations of
Liability for Photoelectric Sensors.
Wiring
The characteristics of the E2K-F will not change if the cable is
extended. Extending the cable, however, will result in a voltage drop,
so do not extend the length past 200 m.
Mounting
Sensitivity Adjustment
For information on the sensitivity adjustment, refer to Technical Guide
for Operation for information for Proximity Sensor.
Timing
chart
Output
circuit
WARNING
Present
Not present
ON
OFF
ON
OFF
Detection
indicator (red)
Sensing
object
Output transistor
(load)
NO Models NC Models
+V
0 V
100 Ω
*
Brown
Black
Output
Blue
Load
Proximity
Sensor
main
circuit
* Load current: 100 mA max.
Precautions for Correct Use
30 mm
45 mm60 mm
Metal
object
Metal
object
Metal
object
50 mm
50 mm
40 mm
Close mounting possible Face-to-face mounting

E2K-F7MC1-10

Mfr. #:
Manufacturer:
Omron Automation and Safety
Description:
Proximity Sensors FLAT PACK CAP PROX. SPECIAL
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: