DC and AC parameters M48Z512A, M48Z512AY, M48Z512AV
14/21 Doc ID 5146 Rev 9
4 DC and AC parameters
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC characteristic
tables are derived from tests performed under the measurement conditions listed in the
relevant tables. Designers should check that the operating conditions in their projects match
the measurement conditions when using the quoted parameters.
Note: Output Hi-Z is defined as the point where data is no longer driven.
Figure 9. AC measurement load circuit
1. Excluding open drain output pins; 50 pF for M48Z512AV.
Table 6. Operating and AC measurement conditions
Parameter M48Z512A/512AY M48Z512AV Unit
Supply voltage (V
CC
) 4.75 to 5.5 V or 4.5 to 5.5 3.0 to 3.6 V
Ambient operating temperature (T
A
)
Grade 1 0 to 70 0 to 70
°C
Grade 6 –40 to 85 –40 to 85
Load capacitance (C
L
) 100 50 pF
Input rise and fall times ≤ 5 ≤ 5ns
Input pulse voltages 0 to 3 0 to 3 V
Input and output timing ref. voltages 1.5 1.5 V
Table 7. Capacitance
Symbol Parameter
(1)(2)
1. Effective capacitance measured with power supply at 5 V (M48Z512A/Y) or 3.3 V (M48Z512AV); sampled
only, not 100% tested.
2. Outputs deselected.
Min Max Unit
C
IN
Input capacitance - 10 pF
C
IO
(3)
3. At 25 °C.
Input/output capacitance - 10 pF
AI03903
C
L
= 100 pF
or 30 pF
(1)
C
L
includes JIG capacitance
650Ω
DEVICE
UNDER
TEST
1.75V