Rev. Date:
21-Jun-13
Rev.:
D
Document No.
CGPE-105
Sheet:
2 of 2
If this document is printed it becomes uncontrolled. Check for the latest revision.
Table 2: Properties
Property Unit Requirements Test Method
1
*Dimensions Inches Table 1 ASTM D 2671
*Tensile Strength psi 1800 minimum ASTM D 2671
20 in./min.
*Ultimate Elongation Percent 200 minimum ASTM D 2671
20 in./min.
*Longitudinal Change Percent 0 to -10 ASTM D 2671
Secant Modulus psi 25,000 maximum ASTM D 2671
Specific Gravity -- 1.0 maximum ASTM D 792
Low Temperature Flexibility, 4 hr./-70C
Followed by mandrel bend
(Use mandrels sizes per TUS-30-3019)
-- No Cracking ASTM D 2671
Procedure C
*Heat Shock, 4 hr./200C
Followed by visual inspection
-- No Dripping, Flowing or
Cracking
ASTM D 2671
Corrosion, Copper Contact
16 hr./125C
-- No Pitting or Blackening
of Copper
ASTM D 2671
Procedure B
Heat Resistance, 168 hr./125C
Followed by Ultimate Elongation
Percent
100 minimum
ASTM D 2671
20 in./min.
Dielectric Strength V/mil 500 minimum ASTM D 2671
*Acceptance Test
1) When testing requiring fully recovered specimens, recover the specimens for 3 minutes @
200°C.
CUSTOMER DRAWING