NCV7520
www.onsemi.com
31
Figure 25. SCB Latch−off & Recovery − Read Status & Request ON Pulse (Timer Running)
Figure 26. SCB Latch−off & Recovery − Read Status & Request OFF Pulse (Timer Running)
SO
GATx
FLTB
INx
0
1
0
1
0
1
0
1
0
1
CSB
0
1
0
1
0
1
DRNx
FLTREF
0
VBAT
DIAG
STATUS
BLANK
TIMER
FILTER
TIMER
100
RSTB
0
1
INTERNAL SIGNALS
001 101
001
100
LATCHED
SCB FAULT NO FAULT
t
FF(ON)
NO FAULT
000
VOL
NO SCB FAULT
110
SCB Latch & Clear 3
ECHO
RE−STARTED
t
BL(ON)
VOL
VSG
t
BL(OFF)
111
DIAG NOT COMPLETE
t
BL(ON)
t
BL(OFF)
Read
UNLATCHED
ON Pulse Req
SO
GATx
FLTB
INx
0
1
0
1
0
1
0
1
0
1
CSB
0
1
0
1
0
1
DRNx
FLTREF
0
VBAT
DIAG
STATUS
BLANK
TIMER
FILTER
TIMER
100
RSTB
0
1
INTERNAL SIGNALS
001 110
001
100
SCB FAULT NO FAULT
t
FF(ON)
NO FAULT
111
VOL
NO SCG/OLF FAULT
t
BL(ON)
SCB Latch & Clear 4
VOL
VSG FLTREF
ECHO
101
LATCHED
000
DIAG NOT COMPLETE
t
BL(OFF)
UNLATCHED
t
BL(OFF)
Read
RE−STARTED
OFF Pulse Req
NCV7520
www.onsemi.com
32
SO
GATx
FLTB
INx
0
1
0
1
0
1
0
1
0
1
CSB
0
1
0
1
0
1
DRNx
FLTREF
0
VBAT
DIAG
STATUS
BLANK/
REFRESH
TIMER
FILTER
TIMER
100
RSTB
0
1
INTERNAL SIGNALS
001 001
001
DIAG NOT COMPLETESCB FAULT
t
FF(ON)
NO FAULT
111
VOL
SCB FAULT
ON/OFF Pulse Req
Ignored During Retry
Don’t Care
Retry 1
t
BL(ON)
t
FR
ECHO
t
FR
VOL
VSG
t
FF(ON)
Figure 27. Auto−retry Timer Started, INx Went Low During Second Retry − Retry Timer Runs to Completion
SO
GATx
FLTB
INx
0
1
0
1
0
1
0
1
0
1
CSB
0
1
0
1
0
1
DRNx
FLTREF
0
VBAT
DIAG
STATUS
BLANK/
REFRESH
TIMER
FILTER
TIMER
100
RSTB
0
1
INTERNAL SIGNALS
001 001
001
DIAG NOT COMPLETESCB FAULT
t
FF(ON)
NO FAULT
111
VOL
SCB FAULT
ON/OFF Pulse Req
Ignored During Retry
Don’t Care
Retry 2
t
BL(ON)
t
FR
ECHO
t
FR
VOL
VSG
001
NOT COMPLETE
111 110
NO SCG/OLF
Figure 28. Auto−retry Timer Started, INx Went Low During Second Retry − Retry Timer Runs to Completion
Status Read Clears SCB, Allows OFF−state Status Update
NCV7520
www.onsemi.com
33
SO
GATx
FLTB
INx
0
1
0
1
0
1
0
1
0
1
CSB
0
1
0
1
0
1
DRNx
VSG
0
VBAT
DIAG
STATUS
BLANK
TIMER
FILTER
TIMER
RSTB
0
1
INTERNAL SIGNALS
111 100
ECHO
NO SCB FAULT
101
VOL
NO FAULT
t
BL(OFF)
VOL
VSG
t
BL(ON)
ON or OFF Pulse Req Ignored
During t
BL(ON|OFF)
Don’t Care
ON Pulse Req
ECHO
FLTREF
DIAG NOT COMPLETE
110
OFF BLANK STARTED TO ALLOW
DRAIN TO SETTLE
Pulse 1
Figure 29. Normal ON Pulse Request & Second Request Ignored − INx Remains in Low State at End of Pulse
SO
GATx
FLTB
INx
0
1
0
1
0
1
0
1
0
1
CSB
0
1
0
1
0
1
DRNx
VSG
0
VBAT
DIAG
STATUS
BLANK
TIMER
FILTER
TIMER
RSTB
0
1
INTERNAL SIGNALS
111 101
ECHO
NO SCB FAULT
VOL
t
BL(ON)
ON Pulse Req
ECHO
FLTREF
DIAG NOT COMPLETE
ECHO
ON Pulse Req
t
BL(ON)
t
BL(OFF)
OFF Pulse Req
ECHO
t
BL(ON)
110 100
NO FAULT
111
Status Req
100
101
NO SCB FAULT
BLANKING NOT RESTARTED
ON BLANK STARTED TO
ALLOW DRAIN TO SETTLE
Pulse 2
ON or OFF
Pulse Req
IGNORED
Figure 30. Normal ON Pulse Request & Second Request Ignored − INx State Change During First Pulse