AUIRS4428S
www.irf.com © 2010 International Rectifier
11
Parameter Trends vs. Temperature
Figures illustrated in this chapter provide information on the experimental performance of the AUIRS4428S HVIC.
The line plotted in each figure is generated from actual lab data. A large number of individual samples were tested at
three temperatures (-40 ºC, 25 ºC, and 125 ºC) with supply voltage of 15V in order to generate the experimental
curve. The line consists of three data points (one data point at each of the tested temperatures) that have been
connected together to illustrate the understood trend. The individual data points on the Typ. curve were determined
by calculating the averaged experimental value of the parameter (for a given temperature).
50
60
70
80
90
-50 -25 0 25 50 75 100 125
Temperature (
o
C)
Turn-on Propagation Delay (ns)
Typ
Max.
Min.
Figure 4. Turn-On Propagation Delay vs. Temperature
45
55
65
75
85
-50-25 0 255075100125
Temperature (
o
C)
Turn-off Propagation Delay (ns
Typ.
Max.
Min.
Figure 5. Turn-Off Propagation Delay vs. Temperature
10
15
20
25
30
-50 -25 0 25 50 75 100 125
Temperature (
o
C)
Torn-On Rise Time (ns)
Typ.
Max.
Min.
Figure 6. Turn-On Rise Time vs. Temperature
15
20
25
30
35
-50 -25 0 25 50 75 100 125
Temperature (
o
C)
Turn-Off fall Time (ns)
Typ.
Max.
Min.
Figure 7. Turn-Off Fall Time vs. Temperature