74LVC4066_Q100 All information provided in this document is subject to legal disclaimers. © NXP B.V. 2012. All rights reserved.
Product data sheet Rev. 1 — 7 August 2012 6 of 23
NXP Semiconductors
74LVC4066-Q100
Quad bilateral switch
[1] All typical values are measured at T
amb
=25C.
[2] These typical values are measured at V
CC
=3.3V.
9.1 Test circuits
9.2 ON resistance
C
I
input
capacitance
- 12.5 - - - pF
C
S(OFF)
OFF-state
capacitance
-8.0- - -pF
C
S(ON)
ON-state
capacitance
- 14.0 - - - pF
Table 6. Static characteristics …continued
At recommended operating conditions voltages are referenced to GND (ground = 0 V).
Symbol Parameter Conditions 40 C to +85 C 40 C to +125 C Unit
Min Typ
[1]
Max Min Max
V
I
= V
CC
or GND and V
O
= GND or V
CC
.V
I
= V
CC
or GND and V
O
= open circuit.
Fig 6. Test circuit for measuring OFF-state leakage
current
Fig 7. Test circuit for measuring ON-state leakage
current
001aag488
I
S
V
I
V
IL
V
O
V
CC
GND
nYnZ
nE
001aag489
I
S
V
I
V
IH
V
O
V
CC
GND
nYnZ
nE
Table 7. ON resistance
At recommended operating conditions; voltages are referenced to GND (ground 0 V); for graphs see Figure 9
to Figure 14.
Symbol Parameter Conditions 40 C to +85 C 40 C to +125 C Unit
Min Typ
[1]
Max Min Max
R
ON(peak)
ON resistance (peak) V
I
=GNDtoV
CC
; see Figure 8
I
SW
=4mA;
V
CC
= 1.65 V to 1.95 V
- 34.0 130 - 195
I
SW
=8mA; V
CC
= 2.3 V to 2.7 V - 12.0 30 - 45
I
SW
=12mA; V
CC
= 2.7 V - 10.4 25 - 38
I
SW
=24mA; V
CC
= 3 V to 3.6 V - 7.8 20 - 30
I
SW
=32mA; V
CC
= 4.5 V to 5.5 V - 6.2 15 - 23