74VHC4051AFT,74VHC4052AFT,74VHC4053AFT
5
8.
8.
8.
8. Truth Table
Truth Table
Truth Table
Truth Table
Input
Inhibit
L
L
L
L
L
L
L
L
H
Input
C*
L
L
L
L
H
H
H
H
X
Input
B
L
L
H
H
L
L
H
H
X
Input
A
L
H
L
H
L
H
L
H
X
ON Channel
74VHC4051AFT
0
1
2
3
4
5
6
7
None
ON Channel
74VHC4052AFT
0X, 0Y
1X, 1Y
2X, 2Y
3X, 3Y
None
ON Channel
74VHC4053AFT
0X, 0Y, 0Z
1X, 0Y, 0Z
0X, 1Y, 0Z
1X, 1Y, 0Z
0X, 0Y, 1Z
1X, 0Y, 1Z
0X, 1Y, 1Z
1X, 1Y, 1Z
None
X: Don't care
*: Except 74VHC4052AFT
9.
9.
9.
9. Absolute Maximum Ratings (Note)
Absolute Maximum Ratings (Note)
Absolute Maximum Ratings (Note)
Absolute Maximum Ratings (Note)
Characteristics
Supply voltage
Input voltage
Switch I/O voltage
Input diode current
I/O diode current
Switch through current
V
CC
/ground current
Power dissipation
Storage temperature
Symbol
V
CC
V
IN
V
I/O
I
IK
I
I/OK
I
T
I
CC
P
D
T
stg
Note
(Note 1)
Rating
-0.5 to 7.0
-0.5 to 7.0
-0.5 to V
CC
+ 0.5
-20
±25
±25
±50
180
-65 to 150
Unit
V
V
V
mA
mA
mA
mA
mW
Note: Exceeding any of the absolute maximum ratings, even briefly, lead to deterioration in IC performance or even
destruction.
Using continuously under heavy loads (e.g. the application of high temperature/current/voltage and the
significant change in temperature, etc.) may cause this product to decrease in the reliability significantly even
if the operating conditions (i.e. operating temperature/current/voltage, etc.) are within the absolute maximum
ratings and the operating ranges.
Please design the appropriate reliability upon reviewing the Toshiba Semiconductor Reliability Handbook
(“Handling Precautions”/“Derating Concept and Methods”) and individual reliability data (i.e. reliability test report
and estimated failure rate, etc).
Note 1: 180 mW in the range of T
a
= -40 to 85 . From T
a
= 85 to 125 a derating factor of -3.25 mW/ shall be
applied until 50 mW.
10.
10.
10.
10. Operating Ranges (Note)
Operating Ranges (Note)
Operating Ranges (Note)
Operating Ranges (Note)
Characteristics
Supply voltage
Input voltage
Switch I/O voltage
Operating temperature
Input rise and fall times
Symbol
V
CC
V
IN
V
S
T
opr
dt/dv
Test Condition
V
CC
= 2.5 ± 0.2 V
V
CC
= 3.3 ± 0.3 V
V
CC
= 5 ± 0.5 V
Rating
2.0 to 5.5
0 to 5.5
0 to V
CC
-40 to 125
0 to 200
0 to 100
0 to 20
Unit
V
V
V
ns/V
Note: The operating ranges must be maintained to ensure the normal operation of the device.
Unused inputs must be tied to either V
CC
or GND.
2017-02-22
Rev.4.0