SERIES: ETMA 250W DESCRIPTION: MEDICAL AC-DC POWER SUPPLY
MODEL
output
voltage
output
current
output
power
ripple
and noise
1
ef ciency
level
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
ETMA1202083U 12 20.83 250 240 V
ETMA1601563U 16 15.63 250 300 V
ETMA1901316U 19 13.16 250 300 V
ETMA2001250U 20 12.5 250 300 V
ETMA2401042U 24 10.42 250 300 V
ETMA360694U 36 6.94 250 300 V
ETMA480521U 48 5.21 250 300 V
Notes: 1. At full load, 100 ~ 240 Vac input, 20 MHz bandwidth oscilloscope, each output terminated with 10 μF aluminum electrolytic and 0.1 μF ceramic capacitors.
FEATURES
• up to 250 W power
• universal input (90~264 Vac)
• single regulated output from 12~48 V
• over voltage, overload and short circuit protections
• full medical safety approvals
• active PFC
• level V efficiency
• custom designs available
PART NUMBER KEY
ETMA1202083U C - P68 - WP - CXX
DC Plug Type
Factory
Designation
Base Number
example of 12 Vdc, 20.83 A
Reserved for Custom
Con gurations
RoHS
Input Cable:
C = included
blank = no cable
cui.com
date 09/04/2013 page 2 of 5CUI Inc SERIES: ETMA 250W DESCRIPTION: MEDICAL AC-DC POWER SUPPLY
INPUT
parameter conditions/description min typ max units
voltage 90 264 Vac
frequency 47 63 Hz
current at 90 Vac, 60 Hz 3.5 A
inrush current at 230 Vac, cold start 150 A
no load power consumption 0.5 W
OUTPUT
parameter conditions/description min typ max units
line regulation ±1 %
load regulation ±5 %
hold-up time at 115 Vac 16 ms
temperature coef cient ±0.05 %/°C
PROTECTIONS
parameter conditions/description
over voltage protection
12 V output
16 V output
19 V output
20 V output
24, 36 V outputs
48 V output
110
110
111
118
110
110
133
130
137
130
125
120
%
%
%
%
%
%
overload protection shutdown and auto restart 110 160 %
short circuit protection continuous, auto restart
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
isolation voltage
input to output for 2 seconds
input to frame ground for 2 seconds
4,242
2,121
Vdc
Vdc
insulation resistance
input to output, at 500 Vdc
input to frame ground, at 500 Vdc
20
20
MΩ
MΩ
safety approvals UL/cUL UL 60601-1, TUV EN 60601-1, CB IEC 60601-1
EMI/EMC FCC Part 18 Class B, EN 60601-1, EN 55011
MTBF at 25°C, max. load 140,000 hours
RoHS compliant yes
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature 050°C
storage temperature -10 70 °C
humidity non-condensing 20 90 %
cui.com
date 09/04/2013 page 3 of 5CUI Inc SERIES: ETMA 250W DESCRIPTION: MEDICAL AC-DC POWER SUPPLY
MECHANICAL DRAWING
104.5
0.5
188.5 0.5
60.0 0.5
units: mm
MECHANICAL
parameter conditions/description min typ max units
dimensions 7.42 x 4.11 x 2.36 (188.5 x 104.5 x 60 mm) inch
weight 1.06 kg
input plug IEC320 / C14