KT Temperature
Controller
KT2 Series
[48×24×98.5mm]
KT9 Series
[96×96×98.5mm]
KT8 Series
[48×96×98.5mm]
KT4H/B Series
[48×48×56mm]
KT4 Series
[48×48×95mm]
KT7 Series
[22.5×75×100mm]
KT4H
KT4B
Your Simple, Accurate and Economical
Temperature Controller
Compact temperature controller (DIN
48×24) that can support pattern control
Additions to KT2 series
Broad lineup of temperature controllers
allow you to satisfy application and space requirements.
Compliance with RoHS Directive
(Sample System Configuration)
FPΣ Programmable Controller
(Panasonic Electric Works)
Up to 31 units can be connected
RS-485
*In the configuration above, the FPΣ requires a
communication cassette (FPG-COM3).
*Modbus is a communication protocol developed for
PLCs by Modicon Inc.
FEATURES
1. Multi-input
Versatile thermocouple, RTD, DC voltage
and DC current input for temperature
detecting sensors
2. Simple operation enables highly
accurate temperature control
All required operations can be enabled
by the front keys and highly accurate PID
control mode ensures an input span of
±0.2%.
3. DIN Rail mounting types are aligned
taking global market demand into
consideration
The KT7 series is equipped with DIN rail
mounting complying to DIN standards.
Furthermore, because its control panel is
compact, the KT7 saves space.
4. Nine step pattern control possible.
For KT2 series, despite DIN 48 × 24 size,
selection is possible of control with fixed
set point and nine step pattern control.
5. Meets market demands for cost-
effectiveness
The KT series offers both economy and
high performance.
6. The KT series complies with UL,
CSA standards and CE marking.
7. Improved visibility and ease of
operation
More compact than before
The KT4H/KT4B series features the
largest PV digit size in the industry.
Visibility is improved with an 11-segment
display. Connectable to a PC, it offers a
full range of control and communication
functions.
8. Communication specification uses
RS485 (Modbus protocol)
KT (AKT2,4,7,8,9,4H,4B)
2
PRODUCT TYPES
1. KT2 Series
* When heating/cooling is selected, alarm output 1 cannot be used.
When the communication function is selected, alarm output 2 cannot be used.
• Part No.
(Ex) Part No. when the optional functions (of Heating/Cooling control: relay contact output + Communications function) is added on to
the basic model are as follows; Part No.: AKT21110101
• Options
Note: When Current input is specified, a shunt resistor (sold separately) is required.
2. KT4 Series
Notes: 1. CT1 or CT2 for current detection is provided as an accessory when heater burn-out alarm function is added.
2. Event output will be shared if you choose alarm output 2 and the heater burnout alarm.
• Part No.
(Ex) Part No. when the optional functions (of Heating/Cooling control: SSR output + Communications function) is added on to the
basic model are as follows; Part No.: AKT41111401
• Options
Note: When Current input is specified, a shunt resistor (sold separately) is required.
Base
model
Power
supply
Sensor
input
Control
output
Alarm
output
Heating/
cooling
control
Heater
burnout
alarm
Commu-
nication
function
Description
AKT2 48 × 24 × 98.5mm
1 100 to 240V AC
Must be
specified
2 24V AC/DC
1 Multi-input (Thermocouple, RTD, DC current and DC voltage)
1 Relay contact output 1a 3A 250V AC
Must be
specified
2 Non-contact voltage output (for SSR drive)
3 Current output
200Blank
When both heating/cooling and communication functions are not added:
Relay contact output (alarm 1): Can be used
Open collector output (alarm 2): Can be used
110Blank
When only heating/cooling function is added:
Relay contact output (alarm 1): Cannot be used
Open collector output (alarm 2): Can be used
1001
When only communication function is added:
Relay contact output (alarm 1): Can be used
Open collector output (alarm 2): Cannot be used
0101
When both heating/cooling and communication functions are added:
Relay contact output (alarm 1): Cannot be used
Open collector output (alarm 2): Cannot be used
Product name Part No.
Shunt resistor (for Current input) AKT4810
Ter minal cover AKT2801
Base
model
Power
supply
Sensor
input
Control
output
Alarm
output
Heating/
cooling
control
Heater
burnout
alarm
Commu-
nications
function
Description
AKT4 48 × 48 × 95mm
1 100 to 240V AC
2 24V AC/DC
1 Multi-input (Thermocouple, RTD, DC Voltage and DC Current)
1 Relay contact output 1a 3A 250V AC
2 Non-contact voltage output (for SSR drive)
3 Current output
1 Relay contact output 1a (Alarm output 1)
2 Relay contact output 1a (Alarm output 2)
0 Not available
4
SSR output 0.3A 250V AC (Heating/Cooling control not supported when 2
alarm output points are selected)
0 Not available
1
5A (Heater burn-out alarm not supported when control output is current
output type/not supported when heating and cooling control is selected)
2
10A (Heater burn-out alarm not supported when control output is current
output type/not supported when heating and cooling control is selected)
3
20A (Heater burn-out alarm not supported when control output is current
output type/not supported when heating and cooling control is selected)
4
50A (Heater burn-out alarm not supported when control output is current
output type/not supported when heating and cooling control is selected)
Not available
1Available
Product name Part No.
Shunt resistor (for Current input) AKT4810
Ter minal cover AKT4801
KT (AKT2,4,7,8,9,4H,4B)
3
3. KT8 Series
Notes: 1. CT1 or CT2 for current detection is provided as an accessory when heater burn-out alarm function is added.
2. If a communication function is added, second main setup is not possible
• Part No.
(Ex) Part No. when the optional functions (of Alarm output; Alarm output 2 + Heating/Cooling control: Current output) are added on to
the basic model are as follows; Part No.: AKT8111230
• Options
Note: When Current input is specified, a shunt resistor (sold separately) is required.
4. KT9 Series
Notes: 1. CT1 or CT2 for current detection is provided as an accessory when heater burn-out alarm function is added.
2. If a communication function is added, second main setup is not possible
• Part No.
(Ex) Part No. when the optional functions (of Alarm output; Alarm output 2 + Heating/Cooling control: Non-contact voltage output) are
added on to the basic model are as follows; Part No.: AKT9111220
• Options
Note: When Current input is specified, a shunt resistor (sold separately) is required.
Base
model
Power
supply
Sensor
input
Control
output
Alarm
output
Heating/cool-
ing control
Heater burn-
out alarm
Communica-
tions function
Description
AKT8 48 × 96 × 98.5mm
1 100 to 240V AC
2 24V AC/DC
1 Multi-input (Thermocouple, RTD, DC Voltage and DC Current)
1 Relay contact output 1a1b 3A 250V AC
2 Non-contact voltage output (for SSR drive)
3 Current output
1 Relay contact output 1a (Alarm output 1)
2 Relay contact output 1a (Alarm output 2)
0 Not available
1 Relay contact output 1a
2 Non-contact voltage output (for SSR drive)
3 Current output
0 Not available
1
5A (Heater burn-out alarm not supported when control output is current
output type/not supported when heating and cooling control is selected)
2
10A (Heater burn-out alarm not supported when control output is current
output type/not supported when heating and cooling control is selected)
3
20A (Heater burn-out alarm not supported when control output is current
output type/not supported when heating and cooling control is selected)
4
50A (Heater burn-out alarm not supported when control output is current
output type/not supported when heating and cooling control is selected)
Not available
1Available
Product name Part No.
Shunt resistor (for Current input) AKT4810
Ter minal cover AKT8801
Base
model
Power
supply
Sensor
input
Control
output
Alarm
output
Heating/cool-
ing control
Heater burn-
out alarm
Communica-
tions function
Description
AKT9 96 × 96 × 98.5mm
1 100 to 240V AC
2 24V AC/DC
1 Multi-input (Thermocouple, RTD, DC Voltage and DC Current)
1 Relay contact output 1a1b 3A 250V AC
2 Non-contact voltage output (for SSR drive)
3 Current output
1 Relay contact output 1a (Alarm output 1)
2 Relay contact output 1a (Alarm output 2)
0 Not available
1 Relay contact output 1a
2 Non-contact voltage output (for SSR drive)
3 Current output
0 Not available
1
5A (Heater burn-out alarm not supported when control output is current
output type/not supported when heating and cooling control is selected)
2
10A (Heater burn-out alarm not supported when control output is current
output type/not supported when heating and cooling control is selected)
3
20A (Heater burn-out alarm not supported when control output is current
output type/not supported when heating and cooling control is selected)
4
50A (Heater burn-out alarm not supported when control output is current
output type/not supported when heating and cooling control is selected)
Not available
1Available
Product name Part No.
Shunt resistor (for Current input) AKT4810
Ter minal cover AKT9801

AKT8112100

Mfr. #:
Manufacturer:
Panasonic
Description:
CONTROL TEMP/PROC RELAY/VOLT OUT
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union