ERZ-C32CK431W

Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
“ZNR” Transient/Surge Absorbers (Type CK)
UL, CSA Rec og nized Components and The A.C. Rated Voltage
Part No.
(UL/CSA Recognized)
Maximum Allowable Voltage Rated Voltage (Vrms)
ACrms (V) DC (V) UL1449 CSA (Class 2221 01)
ERZC32CK201W 130 170 118 118
ERZC32CK241W 150 200 136 136
ERZC32CK271W 175 225 159 159
ERZC32CK361W 230 300 209 209
ERZC32CK391W 250 320 227 227
ERZC32CK431W 275 350 250 250
ERZC32CK471W 300 385 272 272
ERZC32CK511W 320 415 291 291
ERZC32CK621W 385 505 350 350
ERZC32CK681W 420 560 381 381
ERZC32CK751W 460 615 418 418
ERZC32CK781W 485 640 440 440
ERZC32CK821W 510 670 463 463
ERZC32CK911W 550 745 500 500
ERZC32CK951W 575 765 522 522
ERZC40CK201W 130 170 118 118
ERZC40CK241W 150 200 136 136
ERZC40CK271W 175 225 159 159
ERZC40CK361W 230 300 209 209
ERZC40CK391W 250 320 227 227
ERZC40CK431W 275 350 250 250
ERZC40CK471W 300 385 272 272
ERZC40CK511W 320 415 291 291
ERZC40CK621W 385 505 350 350
ERZC40CK681W 420 560 381 381
ERZC40CK751W 460 615 418 418
ERZC40CK781W 485 640 440 440
ERZC40CK821W 510 670 463 463
ERZC40CK911W 550 745 500 500
ERZC40CK951W 575 765 522 522
Mar. 201503
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
“ZNR” Transient/Surge Absorbers (Type CK)
Characteristics Test Methods/Description Specifications
Standard Test Condition
Electrical characteristics shall be measured at following conditions
(Temperature: 5 to 35 °C, Humidity: Max. 85 %).
———
Electrical
Varistor Voltage
The voltage between two terminals with the specified measuring
current 1mA DC applied is called V
1
or V
1mA
. The measurement
shall be made as fast as possible to avoid heat affection.
To meet the
specified value.
Maximum Allowable
Voltage
The maximum sinusoidal wave voltage (rms) or the maximum DC
voltage that can be applied continuously.
Clamping Voltage
The maximum voltage between two terminals with the specified
standard impulse current (8/20 µs).
Rated Power
The maximum power that can be applied within the specified
ambient temperature.
Energy
The maximum energy within the varistor voltage change of ±10 %
when one impulse of 2 ms is applied.
Maximum
Peak
Current
2 times
The maximum current within the varistor voltage change of
±10 % with the standard impulse current (8/20 µs) applied
two times with an interval of 5 minutes.
1 time
The maximum current within the varistor voltage change of ±10 %
with the standard impulse current (8/20 µs) applied one time.
Mechanical
Robustness of
Terminations
(Tensile)
After gradually applying the force of 19.6 N (2 kgf) and keeping
the unit fi xed for ten seconds, the terminal shall be visually
examined for any damage.
No remarkable
damage
Vibration
After repeatedly applying a single harmonic vibration (amplitude:
0.35 mm): double amplitude: 0.7 mm with 1 minute vibration
frequency cycles (10 Hz to 55 Hz to 10 Hz) to each of three
perpendicular directions for 2 hours. Thereafter, the unit shall be
visually examined.
No remarkable
damage
Solderability
After dipping the terminal to a depth of approximately 3 mm from
the body in a soldering bath of 230±5 °C for 5.0±0.5 seconds,
the terminal shall be visually examined.
Approximately 95 %
of the terminals shall
be covered with new
solder uniformly.
Resistance to
Soldering Heat
The terminal shall be dipped into a soldering bath having a
temperature of 350±10 °C to a point 4.0±0.8 mm from the body
of the unit and then be held there for 3.0±0.5 seconds. The
change of Vc and mechanical damage shall be examined.
ΔV
1mA
/V
1mA
<
± 5 %
No remarkable
damage
Environmental
Dry Heat/ High
Temperature
Storage
The specimen shall be subjected to 125±2 °C for 500 hours in a
thermostatic bath without load and then stored at room temperature
and humidity for one to two hours. Thereafter, the change of Vc
shall be measured.
ΔV
1mA
/V
1mA
<
± 5 %
Damp Heat/
Humidity
(Steady State)
The specimen shall be subjected to 40±2 °C, 90 to 95 %RH for
1000 hours without load and then stored at room temperature
and humidity for one to two hours. Thereafter, the change of Vc
shall be measured.
Temperature Cycle
The temperature cycle shown below shall be repeated five
times and then stored at room temperature and humidity for
one to two hours. The change of Vc and mechanical damage
shall be examined.
Step Temperature (°C) Period (minutes)
1–25±3 30
+3
2 Room Temp. 3 max.
3 85±2 30
+3
4 Room Temp. 3 max.
ΔV
1mA
/V
1mA
<
± 5 %
No remarkable
damage
Dry Heat Load/
High Temperature
Load
After being continuously applied the Maximum Allowable Voltage
at 85±2 °C for 500 hours, the specimen shall be stored at room
temperature and humidity for one to two hours. Thereafter, the
change of Vc shall be measured.
ΔV
1mA
/V
1mA
<
± 10 %
0
0
Performance Characteristics (Type CK)
Mar. 201503

ERZ-C32CK431W

Mfr. #:
Manufacturer:
Panasonic
Description:
Varistors ERZC TYPE CK UL CSA RECOGNZD DSK ZNR TAB
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union