CS1W-AT114

!
!
!
!
!
!
!
!
!
!
!
!
SYSMAC CS/CJ-series Programmable Controllers
CS1W-ATjjj Terminal Block Conversion Unit
Instruction Sheet
OMRON Corporation
EOMRON Corporation 2004 All Rights Reserved 0675356-0A
Thank you for purchasing an OMRON Programmable Controller (PLC). To ensure safe operation, please be sure to read the instructions provided in this document along with all
of the user manuals for the Programmable Controller. Please be sure you are using the most recent versions of the user manuals. Contact your nearest OMRON representative
to obtain manuals. Keep this Instruction Sheet and all user manuals in a safe location and be sure that they are readily available to the final user of the products.
General Precautions
The user must operate the product according to the performance specifications de-
scribed in the operation manuals.
Before using the product under conditions which are not described in the manual or
applying the product to nuclear control systems, railroad systems, aviation systems,
vehicles, combustion systems, medical equipment, amusement machines, safety
equipment, petrochemical plants, and other systems, machines, and equipment
that may have a serious influence on lives and property if used improperly, consult
your OMRON representative.
Make sure that the ratings and performance characteristics of the product are suffi-
cient for the systems, machines, and equipment, and be sure to provide the sys-
tems, machines, and equipment with double safety mechanisms.
Safety Precautions
Definition of Precautionary Information
WARNING Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.
Caution Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury, or prop-
erty damage.
Warnings and Cautions
WARNING Do not attempt to take any Unit apart and do not touch any
internal parts while the power is being supplied. Doing so
may result in electric shock.
WARNING Do not touch any of the terminals or terminal blocks while
the power is being supplied. Doing so may result in
electric shock.
WARNING Provide safety measures in external circuits, i.e., not in
the Programmable Controller (CPU Unit including
associated Units; referred to as “PLC”), in order to ensure
safety in the system if an abnormality occurs due to
malfunction of the PLC or another external factor
affecting the PLC operation. Not doing so may result in
serious accidents.
Emergency stop circuits, interlock circuits, limit circuits, and similar safety mea-
sures must be provided in external control circuits.
The PLC will turn OFF all outputs when its self-diagnosis function detects any er-
ror or when a severe failure alarm (FALS) instruction is executed. As a counter-
measure for such errors, external safety measures must be provided to ensure
safety in the system.
The PLC outputs may remain ON or OFF due to deposition or burning of the out-
put relays or destruction of the output transistors. As a countermeasure for such
problems, external safety measures must be provided to ensure safety in the sys-
tem.
Caution Processing speed at the CPU Unit will be different before
and after replacement. This may result in inputs caused
by noise. If necessary, increase the response time while
making sure that it does not interfere with operation.
Caution Processing speed at the CPU Unit will be different before
and after replacement. Operation may not be identical to
that before replacement. Confirm that no problems will
occur due to operation timing.
Operating Environment Precautions
Caution Do not operate the control system in the following places:
Locations subject to direct sunlight
Locations subject to temperatures or humidity outside the range specified
in the specifications
Locations subject to condensation as the result of severe changes in
temperature
Locations subject to corrosive or flammable gases
Locations subject to dust (especially iron dust) or salts
Locations subject to exposure to water, oil, or chemicals
Locations subject to shock or vibration
Caution Take appropriate and sufficient countermeasures when
installing systems in the following locations:
Locations subject to static electricity or other forms of noise
Locations subject to strong electromagnetic fields
Locations subject to possible exposure to radioactivity
Locations close to power lines or power supply lines.
Caution The operating environment of the PLC System can have
a large effect on the longevity and reliability of the system.
Improper operating environments can lead to malfunc-
tion, failure, and other unforeseeable problems with the
PLC System. Be sure that the operating environment is
within the specified conditions at installation and remains
within the specified conditions during the life of the sys-
tem.
Application Precautions
WARNING
Always heed these precautions. Failure to abide by the
following precautions could lead to serious or possibly
fatal injury.
Do not attempt to disassemble, repair, or modify any Units. Any attempt to do
so may result in malfunction, fire, or electric shock.
Caution Failure to abide by the following precautions could lead to
faulty operation of the PLC or the system, or could dam-
age the PLC or PLC Units. Always heed these precau-
tions.
The Terminal Block Conversion Unit (this Unit) is designed specifically for
converting input and output signals from a C500 I/O Unit to those of a CS/CJ-
series I/O Unit. Do not use this Unit for any other purpose.
Confirm that no problems will occur due to differences in specifications be-
tween the I/O Unit prior to replacement and the I/O Unit after replacement.
Otherwise, malfunction may result.
Before mounting the Unit to the control panel, connect the cable between the
CS/CJ-series I/O Unit and this Unit to prevent foreign particles entering the top
connector. Foreign particles may cause malfunction or damage to the Unit.
Confirm that the Unit to be connected at the conversion destination is correct
before connecting the cables. Using incompatible Units may result in malfunc-
tion or damage to the Units.
Mount the Unit only after checking the connectors and terminal blocks com-
pletely. Otherwise malfunction or damage to the Units may result.
Be sure that all the terminal screws and cable connector screws are tightened
to the torque specified in the relevant manuals. Incorrect tightening torque may
result in malfunction.
Use the specified connecting cables to connect the Units. Make sure that any
user-prepared cables are correctly wired. Incorrectly wired cables may cause
failures in external devices or the I/O Unit at the conversion destination.
Always use the power supply voltage specified in the operation manuals. An
incorrect voltage may result in malfunction or burning.
Take appropriate measures to ensure that the specified power with the rated
voltage and frequency is supplied. Be particularly careful in places where the
power supply is unstable. An incorrect power supply may result in malfunction.
Use crimp terminals for wiring. Do not connect bare stranded wires directly to
terminals. Connection of bare stranded wires may result in burning.
Do not apply voltages to the Input Units in excess of the rated input voltage.
Excess voltages may result in burning.
Do not apply voltages or connect loads to the Output Units in excess of the
maximum switching capacity. Excess voltage or loads may result in burning.
Be sure that the terminal blocks, connectors, and other items with locking
devices are properly locked into place. Improper locking may result in malfunc-
tion.
Wire correctly and double-check all the wiring before turning ON the power
supply. Incorrect wiring may result in burning.
Make sure that the lengths of cables are adequate, and provide sufficient
space for wiring. Undue strain on cables may cause the cables to break.
Do not pull on the cables or bend the cables beyond their natural limit. Doing
either of these may break the cables.
Before touching the Unit, be sure to first touch a grounded metallic object in
order to discharge any static electricity build-up. Not doing so may result in
malfunction or damage.
Using the Terminal Block Conversion Unit
The CS1W-ATjjj Terminal Block Conversion Unit is used when replacing a SYSMAC
C500, C1000H, or C2000H PLC with a CS- or CJ-series PLC to allow continued use of
terminal block wiring for the existing I/O Units without modification. When this Unit is used,
rewiring of I/O is not required, significantly reducing the time taken to check wiring work
and conduct test runs.
1. Remove the terminal block (or connector) from the existing C500 I/O Unit
without touching the I/O wiring.
2. Install the removed terminal block (or connector) in the Terminal Block
Conversion Unit, and secure the top and bottom with two fixing screws.
3. Connect the connecting cable to the connector on the top of the Terminal
Block Conversion Unit, and lock it. (Before installing this Unit on the con-
trol panel, connect this connector so that foreign particles do not enter the
connector.)
4. Connect the connecting cable connector to the newly installed CS/CJ-se-
ries I/O Unit and secure with screws.
XW2Z-jjjj
Connecting Cable
CS1W-ATjjj Terminal
Block Conversion Unit
Uses existing terminal block wiring
from C500-series PLCs without
modification.
This reduces rewiring time and the
time taken to check the wiring
work.
Existing C500-,
C1000H-, or
C2000H-series
Basic I/O Units
Remove the terminal block (or connector) from the
existing I/O Unit without touching the I/O wiring.
Existing terminal blocks (or connectors)
Install the removed terminal blocks in the Terminal
Block Conversion Unit.
Uses the same wir-
ing in place prior to
replacement.
Connector- or Terminal Block-type
Basic I/O Units
Newly installed CS- or
CJ-series PLC
Reduces wiring time
by using the same
I/O wiring for CS-
and CJ-series PLCs.
Terminal Block Conversion Unit Models
Always consult the operation manuals of the Unit prior to conversion and the Unit after conversion, and check that differences in specifications will not cause any problems in opera-
tions.
Terminal Block Conversion
Units (CS1W-)
Unit to be
converted (C500-)
Unit at conversion
destination
Connecting
Cable
(XW2Z-)
AT011 16-point DC Input
Conversion Unit
ID112
16 DC inputs
CS1W-MD561
32 TTL inputs/32 TTL
outputs
jjjD
CJ1W-MD563
32 TTL inputs/32 TTL
outputs
jjjN
C200-ID501
32 TTL inputs
jjjA
ID213
16 DC inputs
CS1W-ID231
CJ1W-ID231
32 DC inputs
jjjD
CS1W-ID211
CJ1W-ID211
16 DC inputs
jjjF
IM211
16 AC/DC inputs
Note: Can only
tDCi t
CS1W-ID231
CJ1W-ID231
32 DC inputs
jjjD
Note:
Can
only
convert DC inputs.
CS1W-ID211
CJ1W-ID211
16 DC inputs
jjjF
8-point DC Input
Conversion Unit
C2000–ID216
8 DC inputs
CS1W-INT01
CJ1W-INT01
16 DC inputs
jjjF
16-point Transistor
Output Conversion
Unit
OD217/OD411/OD
219
16 transistor
tt
CS1W-OD231
CJ1W-OD231
32 transistor outputs
jjjL
Unit
16
transistor
outputs
CS1W-OD211
CJ1W-OD211
16 transistor outputs
jjjF
64-point Transistor
Output Conversion
Unit
OD211
64 transistor
outputs
C200H-OD215
In 128-point Dynamic
Output Mode
jjjA
AT031 32-point DC Input
Conversion Unit
ID215/ID218
32 DC inputs
CS1W-ID231
CJ1W-ID231
32 DC inputs
jjjB
IM212
32 AC/DC inputs
Note: Can only
convert DC inputs.
CS1W-ID231
CJ1W-ID231
32 DC inputs
AT032 32-point Transistor
Output Conversion
Unit
OD218/OD412/OD
414
32 transistor
outputs
CS1W-OD231
CJ1W-OD231
32 transistor outputs
jjjB
AT033 32-point Transistor
Output Conversion
Unit (PNP)
OD212
32 transistor
outputs (PNP)
CS1W-OD232
32 transistor outputs
(PNP)
jjjB
AT034 32-point DC Input
Conversion Unit
ID501CN
32 TTL inputs
CS1W-MD561
32 TTL inputs/32 TTL
outputs
jjjD
CJ1W-MD563
32 TTL inputs/32 TTL
outputs
jjjN
C200H–ID501
32 TTL inputs
jjjA
ID218CN
32 DC inputs
CS1W-ID231
CJ1W-ID231
32 DC inputs
jjjD
32-point Transistor
Output Conversion
Unit
OD501CN
32 TTL outputs
CS1W-MD561
32 TTL inputs/32 TTL
outputs
jjjL
Terminal Block Conversion
Units (CS1W-)
Unit to be
converted (C500-)
Unit at conversion
destination
Connecting
Cable
(XW2Z-)
AT034 32-point Transistor
Output Conversion
Unit
OD501CN
32 TTL outputs
CJ1W-MD563
32 TTL inputs/32 TTL
outputs
jjjN
Unit
C200H-OD501
32 TTL outputs
jjjA
OD415CN
32 transistor
outputs
CS1W-OD231
CJ1W-OD231
32 transistor outputs
jjjL
AT035 16-point DC
Input/16-point
Transistor Output
Conversion Units
MD211CN
16 DC inputs/
16 transistor
outputs
CS1W-MD261
32 DC inputs/32
transistor outputs
Input: jjjD
and output:
jjjL
x 1 each
AT061 64-point DC Input
Conversion Unit
ID219
64 DC inputs
CS1W-ID261
CJ1W-ID261
64 DC inputs
jjjB x 2
ID114
64 DC inputs
C200H–ID111
64 DC inputs
64-point Transistor
Output Conversion
Unit
OD213
64 transistor
outputs
CS1W-OD261
CJ1W-OD261
64 transistor outputs
AT111 16-point 100 VAC
inputs conversion to
DC inputs
IA121
16-point 100 VAC
inputs
CS1W-ID231
CJ1W-ID231
32 DC inputs
jjjD
DC
inputs
inputs
CS1W-ID211
CJ1W-ID211
16 DC inputs
jjjF
AT112 16-point 200 VAC
inputs conversion to
DC inputs
IA222
16-point 200 VAC
inputs
CS1W-ID231
CJ1W-ID231
32 DC inputs
jjjD
DC
inputs
inputs
CS1W-ID211
CJ1W-ID211
16 DC inputs
jjjF
AT113 16 relay contact
outputs conversion
to transistor outputs
OC221
16 relay contact
outputs
CS1W-OD231
CJ1W-OD231
32 outputs
jjjL
to
transistor
outputs
outputs
CS1W-OD211
CJ1W-OD211
16 outputs
jjjF
AT114 16 triac outputs
conversion to
transistor outputs
OA121/OA222/
OA226
16 triac outputs
CS1W-OD231
CJ1W-OD231
32 transistor outputs
jjjL
transistor
outputs
16
triac
outputs
CS1W-OD211
CJ1W-OD211
16 transistor outputs
jjjF
AT115 16 relay contact
(independent)
outputs conversion
tt it t t
OC223
16 relay contact
(independent)
tt
CS1W-OD231
CJ1W-OD231
32 transistor outputs
jjjL
outputs
conversion
to transistor outputs
(independent)
outputs
CS1W-OD211
CJ1W-OD211
16 transistor outputs
jjjF
AT131 32-point 100 VAC
inputs conversion to
DC inputs
IA122
32-point 100 VAC
inputs
CS1W-ID231
CJ1W-ID231
32 DC inputs
jjjB
AT132 32-point 200 VAC
inputs conversion to
DC inputs
IA223
32-point 200 VAC
inputs
CS1W-ID231
CJ1W-ID231
32 DC inputs
jjjB
AT133 32 relay contact
outputs conversion
to transistor outputs
OC224
32 relay contact
outputs
CS1W-OD231
CJ1W-OD231
32 transistor outputs
jjjB
AT134 32 triac outputs
conversion to
transistor o tp ts
OA223
24 triac outputs
CS1W-OD231
CJ1W-OD231
32 transistor o tp ts
jjjB
conversion
to
transistor outputs
OA225
32 triac outputs
CJ1W OD231
32 transistor outputs
Diagram of Internal Wiring
CS1W-AT011 CS1W-AT031 CS1W-AT032 CS1W-AT033
Connect terminals A18 and
A19, and supply power to ter-
minal A19 for
C500-OD411/OD211 conver-
sions.
Connect terminals A18 and B18, and
supply power to terminal A18 for
C500-OD412 conversions.
CS1W-AT034 CS1W-AT035 CS1W-AT061 CS1W-AT111/112
Do not wire 4-p terminal
blocks for C500-ID501CN/
ID218CN/OD501CN conver-
sions.
Add a 24-VDC power supply and
connect it between terminals
A18(+) and A19(–).