MAX4621/MAX4622/MAX4623
Dual, 5
Analog Switches
_______________________________________________________________________________________ 7
Pin Description
Applications Information
Operation with Supply Voltages
Other than ±15V
The MAX4621/MAX4622/MAX4623 switches operate with
±4.5V to ±18V bipolar supplies and a +4.5V to +36V sin-
gle supply. In either case, analog signals ranging from
V+ to V- can be switched. The
Typical Operating
Characteristics
graphs show the typical on-resistance
variation with analog signal and supply voltage.
Overvoltage Protection
Proper power-supply sequencing is recommended for all
CMOS devices. It is important not to exceed the absolute
maximum ratings because stresses beyond the listed rat-
ings may cause permanent damage to the devices.
Always sequence V+ on first, followed by V
L
, V-, and
logic inputs. If power-supply sequencing is not possible,
add two small signal diodes in series with the supply pins
and a Schottky diode between V+ and V
L
(Figure 1).
Adding diodes reduces the analog signal range to 1V
below V+ and 1V above V-, but low switch resistance and
low leakage characteristics are unaffected. The differ-
ence between V+ and V- should not exceed +44V.
Negative Supply Voltage14
Ground13
Logic Supply-Voltage Input12
Positive Supply-Voltage Input11
Not internally connected2, 7
Switch Common Terminal1, 3, 6, 8
Negative Supply Voltage
Input
14
Ground13
Positive Supply-Voltage Input11
Not internally connected2, 7
Switch Common Terminal1, 3, 6, 8
Ground
14
Negative Supply Voltage
Input
13
Logic Supply-Voltage Input12
Positive Supply-Voltage Input11
Digital Logic Inputs10, 15
Switch Normally Open
Terminal
9, 16
Not internally connected2–7
Switch Common Terminal1, 8
FUNCTIONPIN
V
g
V
L
NO_
V+
COM_
V-
*
*
*
*
MAX4621
MAX4622
MAX4623
Figure 1. Overvoltage Protection Using Blocking Diodes
*INTERNAL PROTECTION DIODES
V-
GND
V
L
V+
N.C.
COM_
V-
GND
V+
N.C.
COM_
V-
GND
V
L
V+
IN2, IN1
NO2, NO1
N.C.
COM1,
COM2
NAME
NC_, NO_
Switch Normally Closed/Open
Terminal
4, 5, 9, 16
NO_
Switch Normally Open
Terminal
4, 5, 9, 16
V
L
Logic Supply-Voltage Input12
IN2, IN1 Digital Logic Inputs10, 15
IN2, IN1 Digital Logic Inputs10, 15
MAX4621
MAX4622
MAX4623
MAX4621/MAX4622/MAX4623
Dual, 5
Analog Switches
8 _______________________________________________________________________________________
50%
t
OFF
t
r
< 20ns
t
f
< 20ns
V
O
V
O
t
ON
0.9V
O
0.9V
O
+3V
0
V
COM
0
-V
ANA
LOGIC
INPUT
SWITCH
INPUT
SWITCH
OUTPUT
SWITCH
INPUT
LOGIC INPUT WAVEFORM IS INVERTED FOR
SWITCHES THAT HAVE THE OPPOSITE LOGIC
SENSE CONTROL.
+5V +15V
V+
V
O
R
L
= 100
C
L
= 35pF
V-
-15V
REPEAT TEST FOR EACH SWITCH.
0
GND
LOGIC
INPUT
SWITCH
INPUT
IN1
V
COM
= +10V
FOR t
ON
V
COM
= -10V
FOR t
OFF
FOR LOAD CONDITIONS, SEE
Electrical Characteristics.
C
L
INCLUDES FIXTURE AND STRAY CAPACITANCE.
V
O
= V
COM
R
L
R
L
= R
ON
V+V
L
COM_
NC_
OR NO_
V-
MAX4621
MAX4622
MAX4623
50%
V
O1
V
O2
0.9V
O
+3V
0
V
COM
0
V
COM
LOGIC
INPUT
SWITCH
OUTPUT
SWITCH
OUTPUT
+5V
V
L
+15V
V+
NO_
V-
-15V
C
L
INCLUDES FIXTURE AND STRAY CAPACITANCE.
LOGIC 0 INPUT.
0
GND
LOGIC
INPUT
V
COM_
= +10V
0
0.9V
O
t
D
t
D
IN_
R
L2
NC_
C
L2
V
O2
R
L1
V
O1
C
L1
R
L
= 100
C
L
= 35pF
COM_
COM_
MAX4622
V
GEN
GND
NC_ OR NO_
C
L
V
O
0 -15V
V-
V
L
V+
R
GEN
V
O
IN_
ON OFF ON
V
O
Q = (V
O
)(C
L
)
COM
+5V +15V
MAX4621
MAX4622
MAX4623
Figure 2. Switching-Time Test Circuit
Figure 3. MAX4622 Break-Before-Make Test Circuit
Figure 4. Charge-Injection Test Circuit
MAX4621/MAX4622/MAX4623
Dual, 5
Analog Switches
_______________________________________________________________________________________ 9
IN_
0, 2.4V
SIGNAL
GENERATOR
+15V +5V
C
C
V+
V
L
ANALYZER
NC_ OR
NO_
R
L
100
GND
V
COM
C
-15V
FREQUENCY
TESTED
1MHz
SIGNAL
GENERATOR
AUTOMATIC
SYNTHESIZER
ANALYZER
TRACKING SPECTRUM
ANALYZER
OFF-ISOLATION = 20LOG
V
COM
V
NC
OR
V
NO
V-
MAX4621
MAX4622
MAX4623
IN_
0, 2.4V
SIGNAL
GENERATOR
+15V +5V
C
C
V
L
ANALYZER
NC_ OR NO_
R
L
100
GND
COM_
C
V-
-15V
0, 2.4V
IN_
NC_ OR NO_
50
V+
COM_
FREQUENCY
TESTED
1MHz
SIGNAL
GENERATOR
AUTOMATIC
SYNTHESIZER
ANALYZER
TRACKING SPECTRUM
ANALYZER
MAX4621
MAX4622
MAX4623
CAPACITANCE
METER
NC_ OR
NO_
COM_
GND
C
V-
-15V
IN_
0, 2.4V
CC
+15V
V+
+5V
V+ V
L
MAX4621
MAX4622
MAX4623
Figure 5. Off-Isolation
Figure 6. Crosstalk Test Circuit
Figure 8. Channel-Off Capacitance
V-
CAPACITANCE
METER
COM_
GND
C
-15V
IN_
0, 2.4V
CC
+15V +5V
V+
V
L
MAX4621
MAX4622
MAX4623
Figure 7. Channel-On Capacitance

MAX4623CPE

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
Analog Switch ICs Dual 5Ohm Analog Switch