MUSES02
-
-
Ver.2015-04-13
ABSOLUTE MAXIMUM RATINGS (Ta=25°C)
PARAMETER SYMBOL RATING UNIT
Supply Voltage V
+
/V
-
18
V
Common Mode Input Voltage V
ICM
15 (Note1)
V
Differential Input Voltage V
ID
30
V
Power Dissipation P
D
910 mW
Output Current I
O
50
mA
Operating Temperature Range T
opr
-40 to +85 °C
Storage Temperature Range T
stg
-50 to +150 °C
(Note1) For supply Voltages less than 15 V, the maximum input voltage is equal to the Supply Voltage.
RECOMMENDED OPERATING CONDITION (Ta=25°C)
PARAMETER SYMBOL TEST CONDITION MIN. TYP. MAX. UNIT
Supply Voltage V
+
/V
-
-
3.5
-
16
V
ELECTRIC CHARACTERISTICS
DC CHARACTERISTICS (V
+
/V
-
=15V, Ta=25°C unless otherwise specified)
PARAMETER SYMBOL TEST CONDITION MIN. TYP. MAX. UNIT
Operating Current I
cc
No Signal, R
L
=∞ - 8.0 12.0 mA
Input Offset Voltage V
IO
Rs10k (Note2)
- 0.3 3.0 mV
Input Bias Current I
B
(Note2, 3) - 100 500 nA
Input Offset Current I
IO
(Note2, 3) - 5 200 nA
Voltage Gain A
V
R
L
≥2kΩ, V
o
=10V
Rs10k
90 110 - dB
Common Mode Rejection Ratio CMR
V
ICM
=12V (Note4)
Rs10k
80 110 - dB
Supply Voltage Rejection Ratio SVR
V
+
/V
-
=3.5 to 16.0V
Rs10k (Note2, 5)
80 110 - dB
Max Output Voltage V
OM
R
L
=2kΩ
12 13.5
- V
Input Common Mode Voltage
Range
V
ICM
CMR≥80dB
12 13.5
- V
(Note2) Measured at VICM=0V
(Note3) Written by the absolute rate.
(Note4) CMR is calculated by specified change in offset voltage. (VICM=0V to +12V and VICM=0V to −12V)
(Note5) SVR is calculated by specified change in offset voltage. (V+/V−=±3.5V to ±16V)