Technical Data Sheet
7-16
Airline Plug / Jack
60S101-K066
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Page
2 / 3
RF_35/09.14/6.2
Dieses Dokument ist urheberrechtlich geschützt
● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG
Electrical data
Insertion loss ≤ 0.06 dB at 8 GHz
Mechanical data
Mating cycles ≥ 500
Maximum torque 35 Nm
Recommended torque 2.26 Nm
Airline dimensions at 23 °C:
- Diameter outer conductor 16.060 mm ± 0.010 mm
- Diameter inner conductor 6.975 mm ± 0.005 mm
- Length outer conductor 66.00 mm + 0.02 mm
- Length inner conductor 65.98 mm - 0.02 mm
- Length difference ≤ 0.06 mm
(outer conductor – inner conductor)
Calculated data (non warranted)
Lossless characteristic impedance
1
50 Ω ± 0.10 Ω
Return loss
2
≥ 45 dB, 0.2 GHz to 4 GHz
≥ 40 dB, 4 GHz to 8 GHz
1. The lossless characteristic impedance is calculated from the specified diameters of the inner and outer conductor.
2. The return loss is calculated from the characteristic impedance, the skin depth and the connector interface.
General standard definitions
For proper work the vector network analyzer (VNA) used needs a model describing the electrical behaviour
of this calibration standard. Depending on the VNA type different models, units and terms are used
and have to be entered into the VNA. All values are based on typical geometry and plating.
- Offset Z
o
/ Impedance / Z
o
50 Ω
- Offset Delay 220.257 ps
- Length (electrical) / Offset Length 66.031 mm
- Offset Loss 0.70 GΩ/s
- Loss 0.0134 dB/
GHz
Environmental data
Operating temperature range
3
+20 °C to +26 °C
Storage temperature range 0 °C to +50 °C
RoHS compliant
3. This range is a recommendation. However, the airline can be used in a wider range.
Any temperature change from 23 °C results in dimensional changes.