114- 9014
Rev K14 of 18
Consideration must be given to toxicity and safety requirements recommended on the Material Safety Data Sheet
furnished by the solvent manufacturer.
If you have a particular solvent that is not listed, consult an TE Representative before using it on these connectors.
C. Drying
When drying cleaned components and pc boards, make certain the temperature limitations of --55_ to
125_C[--70_ to 260_F] are not exceeded.
D. Soldering Guidelines
Refer to Paragraph 2.6 of this specification for instructional material that is available for establishing
soldering guidelines.
Protect lower shroud (vertical connectors) or lower ground plane (enhanced connector) when soldering right--angle pin
connectors.
3.9. Repair
In the event of damaged contacts or connector, the entire connector must be replaced with a new one, with the
exception of the coaxial contacts in Type M connectors which are removable (refer to Paragraph 5.6).
4. QUALIFICATIONS
Eurocard Connectors meet DIN 41612 and IEC 603--2 specifications. The connectors are also Certified by
CSA International in File LR7189 and Recognized under the Component Program of Underwriters Laboratories
Inc. (UL) in File E28476.
5. TOOLING
5.1. Application Tooling
For low--volume manufacturing, an arbor frame type applicator may be used; for high--volume manufacturing,
machine application is recommended. See Figure 13.
Figure 13
Typical Arbor Frame Press ( Such as Greenerd 3A
or 3B Manual Frame Assembly—refer to 408--9027
for Adapter Kit when using this type press)
“H” Frame Power Unit
Machine 803880--6
SM--3 Machine
814700--2
Power Units
DANGER
NOTE
i
CAUTION
!