6EQ8M

58
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
Highest Performance RFI Filters for Switching Power Supplies
Q Series
Q Series
Maximum leakage current each Line to Ground:
3
& 20A
VQ Models EQ Models
@120 VAC 60 Hz: .73 mA .22 mA
@250 VAC 50 Hz: 1.27 mA .38 mA
6
A
@120 VAC 60 Hz: .29 mA
@250 VAC 50 Hz: .51 mA
Hipot rating (one minute):
Line to Ground: 2250 VDC
Line to Line: 1450 VDC
Rated Voltage (max): 250 VAC
Operating Frequency: 50/60 Hz
Rated Current: 3 to 20A
Operating Ambient Temperature Range
(at rated current I
r
): -10°C to +40°C
In an ambient temperature (T
a
) higher than +40°C
the maximum operating current (I
o
) is calculated as
follows: I
o
= I
r
(85-Ta)/45
• Specificall
y deve
loped for switching power
supplies
• High attenuation for common and differential
mode interference
• Effective from 10kHz to 30MHz
• Optimized for attenuation and size
• 3 or 6A versions available with IEC inlet
Ordering Information
6 E Q 8 M
Suffix
M – Metric inserts (style 8 only)
Omit for standard or none
I
nput / Output Style
1 – .250 [6.3] spade terminals
3 – Wire leads
8 – IEC inlet*
(line side)
Wire leads (load side)
Q Series
Leakage current designation
E – Low leakage (<0.5 mA)
V – Standard
C
urrent Rating
3, 6 or 20A
Specifications
UL Recognized
CSA Certified
VDE Approved
Q8
Available Part Numbers
Q3
3EQ1 6EQ8M
3EQ3 20EQ1
3EQ8 3VQ1
3EQ8M 3VQ3
6EQ1 3VQ8
6EQ3 3VQ8M
6EQ8 20VQ1
Q1
GA400
: NEMA 5-15P to IEC 60320-1 C-13 line cord
Accessories
*IEC 60320-1 C14 inlet mates with C13 connector
59
RFI Power Line Filters
1
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
Highest Performance RFI Filters for Switching Power Supplies (continued)
Q Series
Electrical Schematics
LINE LOAD
3A
LINE LOAD
6, 20A
C
ase Styles
Q1
D
E
A
C
B
C
B
3, 20A Models
6A Models
Q8, Q8M (3A)
A
Tapped insert
D
B
E
C
Brown
Grn/Yel
Blue

 
 
 
Q3
A
D
E
Brown
Blue
Brown
Blue
Grn/Yel
C
B
C
B
Blue
Grn/Yel
Brown
Blue
Grn/Yel
Brown
3A Models
6A Models

 
 
Q8, Q8M (6A)
E
A
D
C
B
Grn/Yel
Blue Brown
Tapped insert
0.63
16.0
.313
7.95
Ref
Ref

 
 
 
 
Part No.
ABCDE
  



3VQ1, 3EQ1
    
    
3VQ3, 3EQ3
    
    
3VQ8/8M,
3EQ8/8M
    
    
6EQ1
    
    
6EQ3
    
    
6EQ8/8M
    
    
20EQ1,
20VQ1
    
    
Case Dimensions


 
 
 
 
60
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
Highest Performance RFI Filters for Switching Power Supplies (continued)
Q Series
Performance Data
Typical Insertion Loss
Minimum Insertion Loss
Common Mode / Asymmetrical (Line to Ground)
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
Measured in closed 50 Ohm system
 
       
         
         
         
       
       
Differential Mode / Symmetrical (Line to Line)
Recommended Panel Cutout
.235
5.96
1.575
40.01
.157
3.98
.910
23.11
Dia. (2)
1.295
32.89
R

 
       
        
        
        
         
         
3VQ
db
100
90
80
70
60
50
40
30
20
10
0
0.01 0.1 1 10 30
Frequency in MHz
3EQ 6EQ 20VQ
db
100
90
80
70
60
50
40
30
20
10
0
0.01 0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0
0.01 0.1 1 10 30
Frequency in MHz
db
100
90
80
70
60
50
40
30
20
10
0
0.01 0.1 1 10 30
Frequency in MHz
20EQ
db
100
90
80
70
60
50
40
30
20
10
0
0.01 0.1 1 10 30
Frequency in MHz

6EQ8M

Mfr. #:
Manufacturer:
TE Connectivity / Corcom
Description:
Power Line Filters 6A IEC IN/WIRE OUT BULKHEAD MNT
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet