TLP150R-96S48FJ

POWER
TLP150 Series
Single Output
Total Power: 150 Watt
Input Voltage: 85 - 264 Vac
# of Outputs: Single
SPECIAL FEATURES
150 W on main channel with only
200 LFM
Low prole ts 1U applications
Active PFC and EN61000-3-2
compliant
Integrated Or-ing diode
Active current sharing
Integrated control and
monitoring features
Overcurrent, overvoltage and
overtemperature protection
Compliance to EN55022-B
conducted noise standard
12 V fan output
5 V standby output (optional)
RoHS compliant
Two year warranty
SAFETY
TUV EN60950-1/IEC60950-1
UL60950-1/CSA22.2 No.60950-1
Electrical Specications
Output
Adjustment range ± 10%
Total regulation
(line and load)
Main output
Auxiliary outputs
Fan output
± 3%
± 5%
± 10%
Turn-on delay @120 Vac input 2.0 s max.
Transient response
Main output
25% to 75%
step at 0.5 A/µs
5%
max. dev., 1 ms max.
recovery to 1%
Temperature coefcient ±0.02%/°C
Overvoltage protection Main outputs 125% ± 5%
Short circuit protection Current limited Continuous
Minimum output current Singles 0 A
Fan voltage output See Note 9 12 V @ 0.5 A
Standby output See Note 9 5 V @ 1.0 A
Input
Input voltage range Universal input 85 - 264 Vac
Input frequency range 47 - 63 Hz
Input surge current 264 Vac (cold start) 40 A max.
Safety ground leakage
current
264 Vac, 50 Hz 1 mA
Input current
100 Vac @ 250 W
120 Vac @ 250 W
230 Vac @ 250 W
2.5 A rms
1.8 A rms
0.8 A rms
Input fuse UL/iEC127 T 3.15 A, 250 Vac
Data Sheet
LPS100-M Series Data Sheet
EMC Characteristics
Conducted emissions EN55022, FCC part 15 Level B
Harmonic current correction EN61000-3-2 Compliant
ESD air EN61000-4-2 Level 3
ESD contact EN61000-4-2 Level 3
Fast transients EN61000-4-4 Level 4
Surge EN61000-4-5 Level 3
Conducted immunity EN61000-4-6 Level 3
General Specications
Hold-up time 85 Vac @ 60 Hz 20 ms @ 150 W
Efciency
115 Vac @ 150 W
230 Vac @ 150 W
81% typ.
84% typ.
Isolation voltage
Input/output
Input/chassis
3000 Vac
1500 Vac
Safety approvals
(see note 6)
UL/cUL UL60950-1/CSA22.2 No. 60950-1
VDE EN60950-1/IEC60950-1
Weight 260g (9.2 oz)
MTBF (@25 ºC)
Telcordia SR-332
MIL-HDBK-217F
900,000 hours min.
350,000 hours min.
Environmental Specications
Thermal performance
Operating ambient,
(See derating curve)
0 °C to +70 °C
Non-operating -40 °C to +85 °C
0 °C to 50 °C ambient,
200 LFM forced air
150 W
0 °C to 50 °C ambient,
convection cooled
100 W
50 °C to 70 °C ambient, Derate linearly to 50% load
Relative humidity Non-condensing 5 - 95% RH
Altitude Operating 10,000 feet max.
Non-operating 30,000 feet max.
Vibration (See Note 7) 5 - 500 Hz 2.4 G rms peak
Shock per MIL-STD-810E 516.4 Part IV
TLP150 Series Data Sheet
Ordering Information
Output
Voltage
Output Currents
Ripple
(3)
Total
Regulation
Model Numbers
(8, 10)
Min Max (free air)
(1, 4)
Max (forced air)
(2, 4)
12 V 0 A 8.4 A 12.5 A 120 mV ± 3.0% TLP150R-96S12J
24 V 0 A 4.2 A 6.3 A 240 mV ± 3.0% TLP150R-96S24J
36 V 0 A 2.7 A 4.2 A 360 mV ± 3.0% TLP150R-96S36J
48 V 0 A 2.1 A 3.2 A 480 mV ± 3.0% TLP150R-96S48J
Notes
1 Free air convection. Maximum continuous output power not to exceed 100W. Refer to Figure 1 for the derating curve.
2 200 LFM forced air cooling from the ac input side. Maximum continuous output power not to exceed 150 W.
3 Figure is peak-to-peak for room temperature rating. Output noise measurements are made across a 20 MHz bandwidth using a 6 inch twisted pair, terminated with a 10 µF
tantalum capacitor and a 0.1 µF ceramic capacitor.
4 CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements. For optimum reliability no part of the heatsink should exceed
115 °C and no semi-conductor case temperature should exceed 120 °C.
5 No external ltering required during conducted emissions testing but some applications may require additional ltering to achieve system compliance. Compliance with
radiated EMI specications may require mounting in a suitable enclosure.
6 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product.
7 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G
8 Replace the ‘J’ at the end of the model number with ‘FJ’ when the optional standby output and/or remote ON/OFF control is required e.g. TLP150R-96S12FJ.
9 12 V (fan) present when main output is present. An optional 5 Vsb (standby) output is available whenever ac input is present, regardless of remote ON/OFF signal status.
10 The ‘J’ sufx indicates that these parts are Pb-free (RoHS 6/6) compliant.
11 NOTICE: Some models do not support all options. Please contact your local Artesyn Embedded Technologies representative or use the on-line model number search tool at
www.artesyn.com/power.
12 Power good signal required 100 mA load on the main output (check with engineering on all models).
13.
This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as a standalone product. EMC
compliance to appropriate standards must be veried at the system level. This product is for sale to OEMs and System Integrators, including through Distribution Channels. It is
not intended for sale to End Users.
DERATING CURVE Output Power (Watts)
Figure 1: Derating Curve
0 C 10 C 20 C 30 C 40 C 50 C 60 C 70 C
100 W
150 W
200 LFM (1.0 m/s)
FORCED AIR COOLING
NATURAL CONVECTION COOLING
50 W
75 W
0 W
Figure 2: Mechanical Drawing
Dimensions in Inches (mm)
ø0.156 (4 Places)
0.225 (5.72)
0.225 (5.72)
J3
1
FAN
1
J4
4.550 (115.57)
5.000 (127.00)
3.000 (76.20)
2.550 (64.77)
J1
J2
1
1.250 (31.75)
Outline Dimensions
1
1
J301
Total Height
R88
Trimmer Adjust
Output Voltage
Ground/Earth
Neutral
Live
Figure 1: Derating Curve

TLP150R-96S48FJ

Mfr. #:
Manufacturer:
Artesyn Embedded Technologies
Description:
Switching Power Supplies 48v 150W 3" x 5" w/ 5V standby output
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: