TLP150 Series Data Sheet
Ordering Information
Output
Voltage
Output Currents
Ripple
(3)
Total
Regulation
Model Numbers
(8, 10)
Min Max (free air)
(1, 4)
Max (forced air)
(2, 4)
12 V 0 A 8.4 A 12.5 A 120 mV ± 3.0% TLP150R-96S12J
24 V 0 A 4.2 A 6.3 A 240 mV ± 3.0% TLP150R-96S24J
36 V 0 A 2.7 A 4.2 A 360 mV ± 3.0% TLP150R-96S36J
48 V 0 A 2.1 A 3.2 A 480 mV ± 3.0% TLP150R-96S48J
Notes
1 Free air convection. Maximum continuous output power not to exceed 100W. Refer to Figure 1 for the derating curve.
2 200 LFM forced air cooling from the ac input side. Maximum continuous output power not to exceed 150 W.
3 Figure is peak-to-peak for room temperature rating. Output noise measurements are made across a 20 MHz bandwidth using a 6 inch twisted pair, terminated with a 10 µF
tantalum capacitor and a 0.1 µF ceramic capacitor.
4 CAUTION: Allow a minimum of 1 second after disconnecting line power when making thermal measurements. For optimum reliability no part of the heatsink should exceed
115 °C and no semi-conductor case temperature should exceed 120 °C.
5 No external ltering required during conducted emissions testing but some applications may require additional ltering to achieve system compliance. Compliance with
radiated EMI specications may require mounting in a suitable enclosure.
6 This product is only for inclusion by professional installers within other equipment and must not be operated as a stand alone product.
7 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G
8 Replace the ‘J’ at the end of the model number with ‘FJ’ when the optional standby output and/or remote ON/OFF control is required e.g. TLP150R-96S12FJ.
9 12 V (fan) present when main output is present. An optional 5 Vsb (standby) output is available whenever ac input is present, regardless of remote ON/OFF signal status.
10 The ‘J’ sufx indicates that these parts are Pb-free (RoHS 6/6) compliant.
11 NOTICE: Some models do not support all options. Please contact your local Artesyn Embedded Technologies representative or use the on-line model number search tool at
www.artesyn.com/power.
12 Power good signal required 100 mA load on the main output (check with engineering on all models).
13.
This product is a Component Power Supply and is only for inclusion by professional installers within other equipment and must not be operated as a standalone product. EMC
compliance to appropriate standards must be veried at the system level. This product is for sale to OEMs and System Integrators, including through Distribution Channels. It is
not intended for sale to End Users.
DERATING CURVE Output Power (Watts)
0 C 10 C 20 C 30 C 40 C 50 C 60 C 70 C
100 W
150 W
200 LFM (1.0 m/s)
FORCED AIR COOLING
NATURAL CONVECTION COOLING
50 W
75 W
0 W
Figure 2: Mechanical Drawing
Dimensions in Inches (mm)
ø0.156 (4 Places)
0.225 (5.72)
0.225 (5.72)
J3
1
FAN
1
J4
4.550 (115.57)
5.000 (127.00)
3.000 (76.20)
2.550 (64.77)
J1
J2
1
1.250 (31.75)
1
1
J301
Total Height
R88
Trimmer Adjust
Output Voltage
Ground/Earth
Neutral
Live
Figure 1: Derating Curve