Nexperia
PESD24VL1BA
Low capacitance bidirectional ESD protection diode in SOD323
10. Application information
The device is designed for the protection of one bidirectional data line from surge pulses and ESD
damage. The device is suitable on lines where the signal polarities are both positive and negative
with respect to ground. The device is not designed to be used on lines connected to a DC supply.
aaa-002737
ESD protection diode
GND
line to be protected
Fig. 7. Application diagram
Circuit board layout and protection device placement
Circuit board layout is critical for the suppression of ESD, Electrical Fast Transient (EFT) and surge
transients. The following guidelines are recommended:
1. Place the device as close to the input terminal or connector as possible.
2. Minimize the path length between the device and the protected line.
3. Keep parallel signal paths to a minimum.
4. Avoid running protected conductors in parallel with unprotected conductors.
5. Minimize all Printed-Circuit Board (PCB) conductive loops including power and ground loops.
6. Minimize the length of the transient return path to ground.
7. Avoid using shared transient return paths to a common ground point.
8. Use ground planes whenever possible. For multilayer PCBs, use ground vias.
11. Package outline
03-12-17Dimensions in mm
0.25
0.10
0.45
0.15
2.7
2.3
1.8
1.6
0.40
0.25
1.1
0.8
1.35
1.15
1
2
Fig. 8. Package outline SOD323
PESD24VL1BA All information provided in this document is subject to legal disclaimers.
©
Nexperia B.V. 2018. All rights reserved
Product data sheet 12 July 2018 7 / 12