LITE-ON TECHNOLOGY CORPORATION
Property of Lite-On Only
Electrical Optical Characteristics at T
A
=25
℃
Parameter Symbol Min. Typ. Max. Unit Test Condition
Luminous Intensity I
V
5.6 19 mcd
I
F
= 10mA
Note 1,4
Viewing Angle
2
θ
1/2
45 deg Note 2 (Fig.6)
Peak Emission Wavelength
λ
P
635 nm
Measurement
@Peak (Fig.1)
Dominant Wavelength
λ
d
615 625 632 nm Note 3
Spectral Line Half-Width
Δλ
40 nm
Forward Voltage V
F
2.0 2.6 V I
F
= 20mA
Reverse Current I
R
100
μ
A
V
R
= 5V
Capacitance C
20 pF V
F
= 0 , f = 1MHz
Note: 1. Luminous intensity is measured with a light sensor and filter combination that approximates the CIE
(Commission International De L'Eclairage) eye-response curve.
2.
θ
1/2
is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
3. The dominant wavelength,
λ
d is derived from the CIE chromaticity diagram and represents the single
wavelength which defines the color of the device.
4. The Iv guarantee should be added
±
15% .
Part No. : LTL-1CHEE Page : 3 of 7
BNS-OD-C131/A4